Drug overdose is the most common method in suicide attempts. Amitriptyline (AMT), a tricyclic antidepressant agent, known for potentially lethal cardiovascular and neurological effects, is used especially by intoxicated patients. The aim of this study was to validate a method for the determination of AMT in gastric lavage samples by high-performance thin-layer chromatography (HPTLC). Artificial gastric lavage was used to obtain a better extraction procedure for AMT. The method was also applied to patients who attempted suicide with AMT. A validated, accurate, and rapid HPTLC-based method was developed for quantitation of AMT in gastric content of intoxicated patients. Extraction was done from 3 mL gastric lavage sample by liquid-liquid extraction procedure with ethyl acetate-/t-heptane (1:1, wlw) in alkaline pH with 10.8. The mobile phase was an isocratic solvent system consisting of methanol-ammonia (25%) (98.5:1.5, v/v). 3,4-Methylenedioxy-N-methamphetamine (MDMA) was used as internal standard (IS). Analytes were quantified by TLC Scanner operating under 209 nm. The retardation factors of AMT and MDMA were determined as 0.49 and 0.25, respectively. The analytical range was set as 10-250 ng spot"1 for AMT. Calibration was linear within the selected range in gastric lavage (r > 0.9995). Limit of detection and limit of quantification of AMT were found to be 5.1 and 17.3 ng spot"1, respectively. Recoveries of 25 ng spot"1 and 100 ng spot"1 concentrations were found 83.12% and 91.89%; bias% values were 10.91 and 3.19, respectively. The validated method was also applied on samples of five patients who attempted suicide by AMT, and concentrations in gastric lavage samples of 5 patients were found 7.1, 8.3, 9.9, 14.6, and 36.6 ng mL'1. This successfully validated method was applied to suicide cases, and it can be conveniently employed on both antemortem and postmortem cases suspected by amitriptyline.
机译:药物过量是自杀尝试中最常见的方法。三环抗抑郁药阿米替林(AMT)以潜在的致命心血管和神经系统作用而闻名,尤其是中毒患者使用。这项研究的目的是验证一种通过高效薄层色谱法(HPTLC)测定洗胃样品中AMT的方法。人工洗胃被用来获得更好的AMT提取程序。该方法还适用于尝试AMT自杀的患者。建立了一种经过验证的,准确且快速的基于HPTLC的方法,用于定量中毒患者胃内的AMT。通过液-液萃取程序,用乙酸乙酯/叔庚烷(1:1,wlw)在碱性pH为10.8中的液-液萃取程序从3 mL胃灌洗样品中萃取。流动相是由甲醇-氨(25%)(98.5:1.5,v / v)组成的等度溶剂系统。 3,4-亚甲基二氧基-N-甲基苯丙胺(MDMA)被用作内标(IS)。通过在209nm下操作的TLC扫描仪定量分析物。 AMT和MDMA的延迟因子分别确定为0.49和0.25。 AMT的分析范围设置为10-250 ng spot“ 1。在选定的洗胃范围内,校准线性(r> 0.9995)。AMT的检出限和定量限为5.1和17.3 ng spot “ 1。发现25 ng spot“ 1和100 ng spot” 1浓度的回收率分别为83.12%和91.89%;偏倚值分别为10.91和3.19。经验证的方法还应用于5例通过AMT自杀的患者的样品中,发现5例患者的洗胃样品中的浓度分别为7.1、8.3、9.9、14.6和36.6 ng mL'1。这种成功验证的方法适用于自杀案,可以方便地用于阿米替林怀疑的死前和死后案件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号