【24h】

Study on warfarin plasma concentration and its correlation with international normalized ratio.

机译:华法林血浆浓度及其与国际标准化比值的相关性研究。

获取原文
获取原文并翻译 | 示例
       

摘要

A sensitive high-performance liquid chromatographic (HPLC) method was developed for warfarin determination in plasma of patients who undertook cardiac valve replacement and were on anticoagulation with warfarin. The method described proved to be accurate, sensitive, easy to perform, reproducible and specific for plasma warfarin measurement with relative standard deviation (R.S.D.) of <5.27% for inter-day and <6.89% for intra-day. The assay was linear in warfarin concentration ranges of 0.12-3 microg/ml (r=0.9995) with mean recovery of 94.6%. The mean warfarin plasma concentration of 58 patients with heart valve replacement within 1 month of post operation was 567.6+/-122.3 ng/ml. The anticoagulant effect of the drug was monitored by international normalized ratio (INR). The correlation of warfarin dosage and concentration with INR was analysed, and the coefficients were 0.21, 0.1<0.2 and 0.30, 0.02<0.1, respectively. The correlation of warfarin dosage or concentration with INR is very poor, and hence in order to adjust the dosage more objectively and accurately, concentration monitoring is necessary and helpful for the patient management. It is needed especially when the ideal INR is difficult to target.
机译:开发了一种灵敏的高效液相色谱(HPLC)方法,用于进行心脏瓣膜置换术并接受华法林抗凝治疗的患者血浆中的华法林测定。所描述的方法被证明是准确,灵敏,易于执行,可重现的并且对血浆华法林测定具有特异性,日间相对标准偏差(R.S.D.)<5.27%,日内<6.89%。该测定法在华法林浓度范围为0.12-3 microg / ml(r = 0.9995)时呈线性,平均回收率为94.6%。术后1个月内有58例心脏瓣膜置换术患者的华法林血浆平均浓度为567.6 +/- 122.3 ng / ml。通过国际标准化比率(INR)监测药物的抗凝作用。分析了华法林剂量和浓度与INR的相关性,其系数分别为0.21、0.1 <0.2和0.30、0.02 <0.1。华法林剂量或浓度与INR的相关性很差,因此,为了更客观,准确地调整剂量,浓度监测是必要的,对患者管理很有帮助。特别是在难以确定理想INR的情况下,这是必需的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号