A simple HPLC method using a microbore column for the analysis of doxorubicin.

机译:使用微孔柱的简单HPLC方法,用于分析阿霉素。

获取原文
获取原文并翻译 | 示例
           

摘要

Doxorubicin is one of the most potent anti-tumor agents generally used in the treatment of bone cancer. A simple and sensitive HPLC method was developed and validated for the assay of doxorubicin. The method used a C18 Luna microbore column (50 x 1 mm) with a fluorescent detector (505 nm Ex. and 550 nm Em.). The mobile phase consisted of water-acetonitrile-acetic acid (80:19:1, v/v/v, pH 3.0) and the flow rate was 0.1 ml min(-1). Daunomycin was used as the internal standard. This isocratic system required a 10-min run-time, giving a detection limit of 0.02 ng (0.035 pmol per injection). Standard curves were linear over the concentration range of 0.01-0.1 microg ml(-1). Relative standard deviations (R.S.D.) for the within-day, day-to-day precision, and the accuracy measurement for the assay were less than 4.0, 3.2, and 4.1%, respectively. This HPLC method was used to study the in vitro release characteristics of doxorubicin from implantable drug delivery system.
机译:阿霉素是通常用于治疗骨癌的最有效的抗肿瘤剂之一。开发了一种简单而灵敏的HPLC方法,并验证了该方法可用于阿霉素的测定。该方法使用带有荧光检测器(505 nm Ex。和550 nm Em。)的C18 Luna微孔柱(50 x 1 mm)。流动相由水-乙腈-乙酸(80:19:1,v / v / v,pH 3.0)组成,流速为0.1 ml min(-1)。道诺霉素被用作内标。该等度系统需要10分钟的运行时间,检测限为0.02 ng(每次进样0.035 pmol)。标准曲线在0.01-0.1 microg ml(-1)的浓度范围内是线性的。日内,每日精度和测定的准确度测量的相对标准偏差(R.S.D.)分别小于4.0%,3.2%和4.1%。该HPLC方法用于研究阿霉素从可植入药物递送系统的体外释放特性。