首页> 外文期刊>Clinical rehabilitation >Dual task interference in estimating the risk of falls and measuring change: a comparative, psychometric study of four measurements.
【24h】

Dual task interference in estimating the risk of falls and measuring change: a comparative, psychometric study of four measurements.

机译:在估计跌倒风险和测量变化中的双重任务干预:四种测量的比较性心理测量研究。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The aim is to examine the validity and reliability of the Timed Up and Go Test with dual task for predicting the risk of falls. Standard values for the TUG with dual task were determined, taking account of age and gender. DESIGN: Validation study. SETTING: Data was recorded for 120 volunteers in an outpatient physiotherapy centre. SUBJECTS: The sample comprised 120 healthy men and women aged 60 to 87 years living at home. Twenty-three subjects selected at random were tested again, after one day and after one week, in order to ascertain the retest reliability. MAIN MEASURES: Berg Balance Scale, times for Timed Up and Go Test with manual dual task (TUGman) and with cognitive dual task (TUGcog). RESULTS: Strong correlations between the TUGman and the BBS (r = -0.72) and between the TUGcog and the BBS (r = -0.66) indicate high criterion validity. The retest reliability of the TUGman (r(T1-T2) = 0.97 and r(T1-T3) = 0.98) and TUGcog (r(T1-T2) = 0.98 and r(T1-T3) = 0.98) is very good. The intra-rater reliability is very high with an ICC = 0.99 for the TUGman and an ICC = 0.94 for the TUGcog. The mean time needed to perform the TUGman is 11.6 s (95% CI 11.2-11.9); the mean time needed to perform the TUGcog is 9.8 s (95% CI 9.5-10.2). CONCLUSIONS: The tests with dual task can be recommended because they possess high criterion validity and very good retest reliability. Faster and simpler performance of the TUG-DT is another factor in its favour.
机译:目的:通过双重任务来检验定时跌落测试的有效性和可靠性,以预测跌倒的风险。确定了双重任务的TUG的标准值,并考虑了年龄和性别。设计:验证研究。地点:在门诊理疗中心记录了120名志愿者的数据。受试者:包括120位年龄在60至87岁之间的健康男性和女性,他们生活在家里。为了确定重测的可靠性,在一天之后和一个星期后,对随机选择的23位受试者进行了再次测试。主要指标:Berg平衡量表,使用手动双重任务(TUGman)和认知双重任务(TUGcog)进行定时测试的时间。结果:TUGman和BBS之间(r = -0.72)和TUGcog和BBS之间(r = -0.66)有很强的相关性,表明标准的有效性很高。 TUGman(r(T1-T2)= 0.97和r(T1-T3)= 0.98)和TUGcog(r(T1-T2)= 0.98和r(T1-T3)= 0.98)的重测可靠性非常好。对于TUGman,ICC = 0.99,对于TUGcog,ICC = 0.94,评估者内部可靠性非常高。执行TUGman所需的平均时间为11.6 s(95%CI 11.2-11.9);执行TUGcog所需的平均时间为9.8秒(95%CI 9.5-10.2)。结论:双重任务测试具有较高的标准效度和很好的重测信度,因此值得推荐。 TUG-DT的更快,更简单的性能是它受到青睐的另一个因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号