Ammonia (NH3) is the main preservative that is added to field and concentrated Latices to prevent the deterioration of properties and, in serious cases, coagulation of latex. Almost all factories monitor NH3 content or alkalinity during processing, as it is an important parameter for trading purposes. Alkalinity is determined by the standard analytical method, acid-based titration, as detailed in ISO 125:2011(E) Natural Rubber Latex Concentrate - Determination of Alkalinity. This method requires a skilled analyst and also the use of chemicals. In addition, the titration involves the subjective determination of the end-point, which may vary with each analyst. Near infrared (N1R) spectroscopy, a rapid, non-chemical and repeatable method, was used in this work. Calibration equations for predicting alkalinity were constructed from the relationship between the absorbance spectra of latex (measured using a portable N1R and a Fourier transform (FT1-NIR spectrometer) and the alkalinity content of the latex. It was found that the best equation obtained using the portable and the FT-N1R spectrometer could be used to predict alkalinity in latex with a coefficient of determination, standard error of prediction and ratio of standard error of validation to the standard deviation of 0.63, 0.101% and 1.62, and 0.97, 0.027% and 6.07, respectively. From the statistics testing for performance measurement as detailed in 15012099:2010, NIR-predicted values were no different from actual values at the 95% confident interval. Moreover, the best equation obtained from the more reliable calibration achieved using the FT-N1R spectrometer is attributed to the longer wavelength range.
机译:氨(NH3)是添加到田间和浓缩胶乳中的主要防腐剂,可防止性能下降,在严重的情况下还可防止乳胶凝结。几乎所有工厂都在处理过程中监控NH3的含量或碱度,因为这是进行贸易的重要参数。碱度通过标准分析方法酸基滴定确定,详细信息请参见ISO 125:2011(E)天然橡胶胶乳浓缩物-碱度的测定。该方法需要熟练的分析人员以及化学药品的使用。另外,滴定涉及终点的主观确定,每个分析人员可能会有所不同。近红外(N1R)光谱是一种快速,非化学且可重复的方法,用于这项工作。根据胶乳的吸收光谱(使用便携式N1R和傅立叶变换(FT1-NIR光谱仪)测量)与胶乳的碱度之间的关系,建立了预测碱度的校准方程式。便携式和FT-N1R光谱仪可用于测定乳胶中的碱度,其测定系数,预测标准误差和验证标准误差与标准偏差的比分别为0.63、0.101%和1.62,以及0.97、0.027%和根据15012099:2010中详细介绍的性能测量统计测试,在95%置信区间内,NIR预测值与实际值没有任何不同;此外,通过使用FT获得的更可靠的校准获得的最佳方程式-N1R光谱仪归因于更长的波长范围。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号