首页> 外文期刊>Journal of magnetic resonance imaging: JMRI >Novel application of T1-weighted BLADE sequences with fat suppression compared to TSE in contrast-enhanced T1-weighted imaging of the neck: Cutting-edge images?
【24h】

Novel application of T1-weighted BLADE sequences with fat suppression compared to TSE in contrast-enhanced T1-weighted imaging of the neck: Cutting-edge images?

机译:与TSE相比,具有T1加权BLADE序列的脂肪抑制与TSE相比在颈部对比度增强的T1加权成像中的新应用:尖端图像?

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To evaluate if the use of BLADE sequences might overcome some limitations of magnetic resonance imaging (MRI) in the extracranial head and neck, which is a diagnostically challenging area with a variety of artifacts and a broad spectrum of potential lesions. Materials and Methods: After informed consent and Institutional Review Board approval, two different BLADE sequences with (BLADE IR) and without inversion pulse (BLADE) were compared to turbo-spin echo (TSE) with fat saturation for coronal T1-weighted postcontrast imaging of the extracranial head and neck region in 40 individuals of a routine patient collective. Visual evaluation of image sharpness, motion artifacts, vessel pulsation, contrast of anatomic structures, contrast of pathologies to surrounding tissue as well as BLADE-specific artifacts was performed by two experienced, independent readers. Statistical evaluation was done by using the Wilcoxon test. Results: Both BLADE and BLADE IR were significantly superior to TSE regarding pulsation artifacts and delineation of thoracic structures. TSE provided better results concerning contrast muscle/fat tissue and contrast lymph nodes/fat. More important, it showed significantly better contrast of several lesions, facilitating the detection of patient pathology. Conclusion: T1-weighted coronal imaging of the extracranial head and neck region is demanding. T1-weighted BLADE sequences still have drawbacks in anatomical contrast and lesion detection but offer possibilities to achieve reasonable image quality in difficult cases with a variety of artifacts.
机译:目的:评估使用BLADE序列是否可以克服颅外头颈磁共振成像(MRI)的某些局限性,这是一个诊断困难的领域,存在各种伪像和广泛的潜在病变。材料和方法:在知情同意和机构审查委员会批准后,将两种不同的具有(BLADE IR)和不具有反转脉冲(BLADE)的BLADE序列与具有脂肪饱和度的涡轮自旋回波(TSE)进行冠状动脉T1加权造影后成像常规患者集体的40个人的颅外头颈区域。由两名经验丰富的独立读者对图像清晰度,运动伪影,脉动脉搏,解剖结构对比,与周围组织的病理对比以及BLADE特定伪影进行视觉评估。使用Wilcoxon检验进行统计评估。结果:在搏动伪影和胸腔结构描绘方面,BLADE和BLADE IR均显着优于TSE。 TSE在对比肌/脂肪组织和对比淋巴结/脂肪方面提供了更好的结果。更重要的是,它显示出多个病变的对比度明显更好,从而有助于检测患者的病理状况。结论:颅外头颈区域的T1加权冠状位成像要求很高。 T1加权的BLADE序列在解剖学对比和病变检测方面仍然存在缺陷,但在具有各种伪影的困难情况下提供了实现合理图像质量的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号