...
首页> 外文期刊>Journal of magnetic resonance imaging: JMRI >Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain.
【24h】

Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain.

机译:脑中分数各向异性和痕量扩散张量成像测量的可重复性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To evaluate within-scanner and between-scanner reliability of fractional anisotropy (FA) and trace (sum of the diagonal elements of the diffusion tensor) as measured by diffusion tensor imaging (DTI). MATERIALS AND METHODS: Ten young healthy adults were scanned on three separate days, on two different systems made by the same manufacturer. One scan was acquired at one site, and two scans were acquired on two different occasions on another scanner at another site. Three levels of analysis were used to compare the DTI metrics: 1) a voxel-by-voxel analysis of all supratentorial brain (gray matter + white matter + cerebrospinal fluid) and of supratentorial white matter; 2) a slice-by-slice analysis of supratentorial white matter; and 3) a single-region analysis of the corpus callosum. RESULTS: The voxel-by-voxel analysis of all supratentorial brain found that FA and trace measures and correlations were equivalently and significantly higher within than across scanners. For supratentorial white matter, FA was similar within and across scanners, whereas trace demonstrated across-scanner bias. A similar pattern was observed for the slice-by-slice comparison. For the single-region analysis of the corpus callosum, within-scanner FA and trace measures were highly reproducible for FA (CV = 1.9%) and trace (CV = 2.6%), but both DTI measures showed a systematic mean bias across scanners (CV = 4.5% for FA and CV = 7.5% for trace). CONCLUSION: These estimates of measurement variation and scanner bias can be used to predict effect sizes for longitudinal and multisite studies using diffusion tensor imaging. J. Magn. Reson. Imaging 2003;18:427-433.
机译:目的:评估弥散张量成像(DTI)测量的分数各向异性(FA)和迹线(弥散张量的对角元素之和)在扫描仪内部和扫描仪之间的可靠性。材料与方法:在同一制造商制造的两种不同系统上,分别在三天内对十名年轻健康成年人进行了扫描。在一个站点上进行了一次扫描,而在另一站点上的另一台扫描程序在两次不同的情况下进行了两次扫描。使用三个层次的分析来比较DTI指标:1)对所有剑上脑(灰质+白质+脑脊液)和幕上白质进行逐像素分析。 2)幕上白质的逐层分析; 3)call体的单区域分析。结果:对所有剑上脑的逐个体素分析发现,FA和痕量测度及相关性在扫描仪内部均相等且显着高于扫描仪。对于幕上白质,FA在扫描仪内和扫描仪之间相似,而示踪则显示出扫描仪之间存在偏差。逐片比较观察到相似的模式。对于call体的单区域分析,扫描仪内FA和痕量测量值对FA(CV = 1.9%)和痕量(CV = 2.6%)的重现性很高,但两种DTI测量值均显示了整个扫描仪的系统平均偏差(对于FA,CV = 4.5%,对于痕量,CV = 7.5%。结论:这些测量变化和扫描仪偏差的估计值可用于预测使用扩散张量成像的纵向和多站点研究的效应大小。 J.Magn。雷森成像2003; 18:427-433。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号