To investigate the suppression effect of charged water mist on gas explosion, a small charged water mist generator and a gas explosion simulation device were designed based on the principle of electrostatic induction. Experiments for testing characteristics of the gas explosion in a confined space under different charged polarities, charged voltages and mist fluxes were carried out. Experimental results indicated that, compared with the normal water mist, the explosion peak overpressure and the flame propagation speed could be more effectively reduced by the charged water mist. And this suppression effect could be promoted by increasing the charged voltage. To visualize the effect of the charged water mist's polarity on gas explosion, comparative experiments were conducted. The results showed that the explosion peak overpressure, the overpressure rising rate, and the propagation speed of the flame were reduced by 64.7%, 33.0% and 19.4%, respectively, when a +8 kV charged voltage was applied. In situation where a -8 kV charged voltage was applied, 64.1%, 26.5% and 16.0% reductions were achieved for the explosion peak overpressure, the overpressure rising rate, and the flame propagation speed respectively. Comparison of this data leads to the conclusion that the gas explosion could be more efficiently suppressed by the positively charged water mist. Crown Copyright (C) 2016 Published by Elsevier Ltd. All rights reserved.
机译:为了研究带电水雾对气体爆炸的抑制效果,基于静电感应原理,设计了小型带电水雾发生器和气体爆炸模拟装置。进行了在密闭空间中以不同的带电极性,带电电压和雾通量测试气体爆炸特性的实验。实验结果表明,与普通水雾相比,带电水雾可以更有效地降低爆炸峰值超压和火焰传播速度。并且可以通过增加充电电压来促进这种抑制效果。为了可视化带电水雾的极性对气体爆炸的影响,进行了对比实验。结果表明,在施加+8 kV充电电压时,爆炸峰值超压,超压上升速率和火焰传播速度分别降低了64.7%,33.0%和19.4%。在施加-8 kV充电电压的情况下,爆炸峰值超压,超压上升率和火焰传播速度分别降低了64.1%,26.5%和16.0%。比较这些数据得出的结论是,带正电的水雾可以更有效地抑制气体爆炸。 Crown版权所有(C)2016,由Elsevier Ltd.发行。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号