Smoke control of a fire in a tunnel with vertical shaft

机译:竖井隧道火灾的烟气控制

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this research is to find the optimum smoke extraction rate through the ventilation shaft in case of a fire in a long road tunnel. Furthermore, it is also investigated whether the current emergency ventilation design practice using a vertical shaft can limit the smoke propagation from a fully loaded gasoline tank lorry fire. For this research, scaled model experiments were carried out using a 20 m- long model tunnel with a vertical shaft. A CFD modeling tool was also extensively utilized to investigate the extremely dangerous situation in which a fully loaded gasoline tank lorry is burning inside a long road tunnel.
机译:这项研究的目的是在长距离隧道着火的情况下,通过通风井找到最佳排烟率。此外,还研究了当前使用竖井的紧急通风设计实践是否可以限制满载汽油罐车着火时烟雾的扩散。对于这项研究,使用具有竖井的20 m长模型隧道进行了比例模型实验。还广泛使用了CFD建模工具来调查极端危险的情况,在这种情况下,满载的汽油罐卡车正在长路隧道内燃烧。