Explosion pressures are determined for rich methane-air mixtures at initial pressures up to 30 bar and at ambient temperature. The experiments are performed in a closed spherical vessel with an internal diameter of 20 cm. Four different igniter positions were used along the vertical axis of the spherical vessel, namely at 1, 6, 11 and 18 cm from the bottom of the vessel. At high initial pressures and central ignition a sharp decrease in explosion pressures is found upon enriching the mixture, leading to a concentration range with seemingly low explosion pressures. It is found that lowering the ignition source substantially increases the explosion pressure for mixtures inside this concentration range, thereby implying that central ignition is unsuitable to determine the explosion pressure for mixtures approaching the flammability limits.
机译:确定初始压力最高为30 bar且环境温度为高的甲烷-空气混合物的爆炸压力。实验在内径为20 cm的封闭球形容器中进行。沿球形容器的垂直轴使用了四个不同的点火器位置,即距容器底部1、6、11和18 cm。在高初始压力和中央点火条件下,混合物富集后爆炸压力急剧下降,导致浓度范围看似较低的爆炸压力。已经发现,降低点火源会大大增加该浓度范围内混合物的爆炸压力,从而暗示中心点火不适用于确定接近易燃极限的混合物的爆炸压力。