摘要

BACKGROUND: Over 75,000 patients have undergone deep brain stimulation (DBS) procedures worldwide. Magnetic resonance imaging (MRI) is an important clinical and research tool in analyzing electrode location, documenting postoperative complications, and investigating novel symptoms in DBS patients. Functional MRI may shed light on the mechanism of action of DBS. MRI safety in DBS patients is therefore an important consideration. METHODS: We report our experience with MRI in patients with implanted DBS hardware and examine the literature for clinical reports on MRI safety with implanted DBS hardware. RESULTS: A total of 262 MRI examinations were performed in 223 patients with intracranial DBS hardware, including 45 in patients with an implanted pulse generator. Only 1 temporary adverse event occurred related to patient agitation and movement during immediate postoperative MR imaging. Agitation resolved after a few hours, and an MRI obtained before implanted pulse generator implantation revealed edema around both electrodes. Over 4000 MRI examinations in patients with implanted DBS hardware have been reported in the literature. Only 4 led to adverse events, including 2 hardware failures, 1 temporary and 1 permanent neurological deficit. Adverse neurological events occurred in a unique set of circumstances where appropriate safety protocols were not followed. MRI guidelines provided by DBS hardware manufacturers are inconsistent and vary among devices. CONCLUSIONS: The importance of MRI in modern medicine places pressure on industry to develop fully MRI-compatible DBS devices. Until then, the literature suggests that, when observing certain precautions, cranial MR images can be obtained with an extremely low risk in patients with implanted DBS hardware.
机译:背景:全世界有超过75,000名患者接受了深部脑刺激(DBS)程序。磁共振成像(MRI)是分析电极位置,记录术后并发症和调查DBS患者新症状的重要临床和研究工具。功能性MRI可以阐明DBS的作用机制。因此,DBS患者的MRI安全性是重要的考虑因素。方法:我们报告了我们在植入DBS硬件的患者中的MRI经验,并研究了有关植入DBS硬件的MRI安全性的临床报道。结果:对223例颅内DBS硬件患者进行了262次MRI检查,其中45例植入了脉冲发生器的患者进行了MRI检查。术后立即进行MR成像期间,仅发生1例与患者激动和运动有关的暂时性不良事件。几个小时后躁动消失,在植入脉冲发生器植入之前获得的MRI显示两个电极周围都有水肿。文献中已经报道了对植入DBS硬件的患者进行的4000多次MRI检查。仅4例导致不良事件,包括2例硬件故障,1例临时性和1例永久性神经功能缺损。不良神经事件发生在没有遵循适当安全协议的独特情况下。 DBS硬件制造商提供的MRI指南不一致,并且在设备之间有所不同。结论:MRI在现代医学中的重要性给行业带来了开发完全兼容MRI的DBS设备的压力。直到那时,文献表明,在遵守某些预防措施的情况下,在植入DBS硬件的患者中获得颅骨MR图像的风险极低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号