...
首页> 外文期刊>Journal of Infection >Identification and susceptibility testing of microorganism by direct inoculation from positive blood culture bottles by combining MALDI-TOF and Vitek-2 Compact is rapid and effective
【24h】

Identification and susceptibility testing of microorganism by direct inoculation from positive blood culture bottles by combining MALDI-TOF and Vitek-2 Compact is rapid and effective

机译:通过直接将阳性血液培养瓶中的微生物与MALDI-TOF和Vitek-2 Compact结合直接进行鉴定和药敏测试,是快速有效的

获取原文
获取原文并翻译 | 示例

摘要

Objectives: The objective of this study was to evaluate the reliability and accuracy of the combined use of MALDI-TOF MS bacterial identification and the Vitek-2 Compact antimicrobial susceptibility testing (AST) directly from positive blood cultures. Methods: Direct identification by MALDI-TOF MS and AST were performed in parallel to the standard methods in all positively flagged blood cultures bottles during the study period. Results: Three hundred and twenty four monomicrobial positive blood cultures were included in the present study, with 257 Gram-negative and 67 Gram-positive isolates. MALDI-TOF MS identification directly from blood bottles reported the correct identification for Enterobacteriaceae in 97.7%, non-fermentative Gram-negative bacilli 75.0%, Staphylococcus aureus 75.8%, coagulase negative staphylococci 63.3% and enterococci 63.3%. A total 6156 isolate/antimicrobial agent combinations were tested. Enterobacteriaceae group and non-fermentative Gram-negative Bacilli showed an agreement of 96.67% and 92.30%, respectively, for the Gram-positive cocci the overall agreement found was 97.84%. Conclusions: We conclude that direct identification by MALDI-TOF and inoculation of Vitek-2 Compact AST with positive blood culture bottles yielded very good results and decreased time between initial inoculation of blood culture media and determination of the antibiotic susceptibility for Gram-negative rods and Gram-positive cocci causing bacteremia.
机译:目的:本研究的目的是直接从阳性血培养物中评估结合使用MALDI-TOF MS细菌鉴定和Vitek-2 Compact抗菌药敏试验(AST)的可靠性和准确性。方法:在研究期间,在所有带有阳性标志的血液培养瓶中,与标准方法并行进行了MALDI-TOF MS和AST的直接鉴定。结果:本研究包括234株单微生物阳性血液培养物,其中257株革兰阴性和67株革兰阳性。直接从血瓶进行的MALDI-TOF MS鉴定报告正确鉴定了肠杆菌科的细菌为97.7%,非发酵革兰阴性杆菌为75.0%,金黄色葡萄球菌为75.8%,凝固酶阴性葡萄球菌为63.3%,肠球菌为63.3%。总共测试了6156个分离物/抗菌剂组合。肠杆菌科组和非发酵性革兰氏阴性杆菌分别显示出96.67%和92.30%的一致性,革兰氏阳性球菌的总体一致性为97.84%。结论:我们得出的结论是,通过MALDI-TOF直接鉴定并用阳性血培养瓶接种Vitek-2 Compact AST产生了很好的结果,并缩短了从最初接种血培养培养基到确定革兰氏阴性棒和革兰氏阳性球菌引起菌血症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号