首页> 外文期刊>Journal of Hand Surgery. American Volume >The effects of experimental neurolysis on ectopic firing in a rat chronic constriction nerve injury model.
【24h】

The effects of experimental neurolysis on ectopic firing in a rat chronic constriction nerve injury model.

机译:实验性神经溶解对大鼠慢性收缩神经损伤模型中异位放电的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: We studied the effects of experimental neurolysis on ectopic firing in a rat chronic constriction nerve injury (CCI) model. METHODS: Sixteen Wistar rats were used as CCI models; 8 in a neurolysis group and 8 in a sham operation group. Eight additional Wistar rats were used in a normal control group. The CCI model was created by loosely ligating the sciatic nerve with 4-0 chromic gut sutures. Seven days after surgery the same portion of the sciatic nerve, now embedded in scar tissue, was exposed. For the neurolysis group all sutures and scar tissue around the nerve were removed, and for the sham operation group only exposure of the sciatic nerve embedded in scar tissue was performed. Fourteen days after the first surgery the spinal cords of all animals in the 3 groups were transeated at the most rostral level of the spinal cord and ectopic firing was recorded antidromically from the sural nerve. The spontaneous ectopic firing frequency and the firing pattern at rest and the ectopic firing frequency under a hypoxic condition were analyzed. RESULTS: The ectopic firing frequency in the neurolysis group was significantly lower than that of the sham operation group but higher than that of the normal control group. Also the appearance rate of an on-off pattern was 0% in the neurolysis and normal control groups and 38% in the sham operation group. Finally the accumulated number of ectopic firings under a hypoxic condition was significantly smaller in the neurolysis and normal control groups than that of the sham operation group. CONCLUSIONS: Experimental neurolysis significantly improved the abnormal ectopic firing frequency and on-off firing pattern in the injured nerve of the CCI model. These findings may explain the efficacy of neurolysis on sensory symptoms such as numbness or spontaneous pain in chronic compression neuropathy.
机译:目的:我们研究了大鼠慢性收缩神经损伤(CCI)模型中实验性神经溶解对异位射击的影响。方法:采用16只Wistar大鼠作为CCI模型。神经溶解组8例,假手术组8例。在正常对照组中使用另外八只Wistar大鼠。通过将坐骨神经与4-0铬肠缝合线松散结扎来创建CCI模型。手术后七天,暴露在疤痕组织中的坐骨神经的同一部分被暴露。对于神经溶解组,去除了神经周围的所有缝合线和疤痕组织,对于假手术组,仅暴露了嵌入在疤痕组织中的坐骨神经。第一次手术后第十四天,将三组中所有动物的脊髓均在脊髓的最高鼻侧水平转位,并通过腓肠神经记录抗异位放电。分析了低氧条件下的自发性异位放电频率,静止模式和异位放电频率。结果:神经溶解组的异位放电频率明显低于假手术组,但高于正常对照组。在神经溶解和正常对照组中,开关模式的出现率为0%,在假手术组中为38%。最后,神经溶解和正常对照组在低氧条件下的异位放电累积次数明显少于假手术组。结论:实验性神经溶解可显着改善CCI模型受损神经的异常异位放电频率和开关模式。这些发现可能解释了神经溶解对慢性压迫性神经病中的麻木或自发性疼痛等感觉症状的功效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号