...
首页> 外文期刊>Journal of hypertension >What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?
【24h】

What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?

机译:使用自动示波设备连续两次读取家庭血压之间的最佳间隔是多少?

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To clarify whether a shorter interval between three successive home blood pressure (HBP) readings (10 s vs. 1 min) taken twice a day gives a better prediction of the average 24-h BP and better patient compliance. DESIGN: We enrolled 56 patients from a hypertension clinic (mean age: 60 +/- 14 years; 54% female patients). The study consisted of three clinic visits, with two 4-week periods of self-monitoring of HBP between them, and a 24-h ambulatory BP monitoring at the second visit. Using a crossover design, with order randomized, the oscillometric HBP device (HEM-5001) could be programmed to take three consecutive readings at either 10-s or 1-min intervals, each of which was done for 4 weeks. Patients were asked to measure three HBP readings in the morning and evening. All the readings were stored in the memory of the monitors. RESULTS: The analyses were performed using the second-third HBP readings. The average systolic BP/diastolic BP for the 10-s and 1-min intervals at home were 136.1 +/- 15.8/77.5 +/- 9.5 and 133.2 +/- 15.5/76.9 +/- 9.3 mmHg (P = 0.001/0.19 for the differences in systolic BP and diastolic BP), respectively. The 1-min BP readings were significantly closer to the average of awake ambulatory BP (131 +/- 14/79 +/- 10 mmHg) than the 10-s interval readings. There was no significant difference in patients' compliance in taking adequate numbers of readings at the different time intervals. CONCLUSION: The 1-min interval between HBP readings gave a closer agreement with the daytime average BP than the 10-s interval.
机译:目的:为明确每天两次两次连续两次家庭血压(HBP)读数之间的间隔时间较短(10 s与1分钟),是否可以更好地预测平均24小时血压和更好的患者依从性。设计:我们从高血压诊所招募了56名患者(平均年龄:60 +/- 14岁; 54%为女性患者)。该研究包括三次门诊,两次之间为期4周的HBP自我监测,第二次门诊为24小时动态BP监测。使用交叉顺序随机分配的交叉设计,可以将示波法HBP设备(HEM-5001)编程为以10秒或1分钟的间隔获取三个连续的读数,每个读数进行4周。要求患者在早晨和傍晚测量三个HBP读数。所有的读数都存储在监视器的存储器中。结果:分析是使用第二个HBP读数进行的。在家中10秒和1分钟间隔的平均收缩压/舒张压为136.1 +/- 15.8 / 77.5 +/- 9.5和133.2 +/- 15.5 / 76.9 +/- 9.3 mmHg(P = 0.001 / 0.19分别表示收缩压和舒张压的差异。 1分钟的BP读数比10秒的间隔读数显着接近清醒的非卧床血压的平均值(131 +/- 14/79 +/- 10 mmHg)。在不同的时间间隔获取足够数量的读数,患者的依从性没有显着差异。结论:HBP读数之间的1分钟间隔与白天平均BP的间隔比10秒间隔更接近。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号