首页> 外文期刊>Journal of Geophysical Research, D. Atmospheres: JGR >A new application of a multifrequency submillimeter radiometer in determining the microphysical and macrophysical properties of volcanic plumes: A sensitivity study
【24h】

A new application of a multifrequency submillimeter radiometer in determining the microphysical and macrophysical properties of volcanic plumes: A sensitivity study

机译:多频亚毫米波辐射计在确定火山羽微物理和宏观物理特性方面的新应用:敏感性研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

[1] In this paper, the potential of a multifrequency submillimeter radiometer to characterize ash plumes in the near-field of a volcanic eruption is evaluated. The radiometer's sensitivity to mass concentration and particle effective dimension is shown to depend most critically on aerosol altitude and ejected water vapor concentration. There is also some dependence on temperature, aerosol shape and complex refractive index. For this study, the volcanic aerosols are assumed to be randomly oriented solid hexagonal silicates of aspect ratio unity. The T-matrix method is used to calculate the single-scattering properties of the aerosols at 36 frequencies between 90 GHz and 880 GHz, and the aerosol bulk scattering properties are derived assuming lognormal size distribution functions. A midlatitude standard summer atmosphere and a perturbed midlatitude summer atmosphere are used to quantify the sensitivity, using the delta-Eddington two-stream approximation, of the radiometer to the presence of aerosol. It is shown that at 34 frequencies, between 113 GHz and 880 GHz, the sensitivity to aerosol is a maximum if the following four conditions are satisfied: (i) The altitude of the aerosol layer should be 3 km, (ii)0.1 g m-3 < mass concentration < 30 g m-3(iii)the aerosol effective dimension, De, 20 μm < De < 1000 μm and(iv)water vapor ejected by a volcano into the atmosphere should be < 1000 times greater than the background water vapor concentration. The paper demonstrates the potential usefulness of using spectrally resolved submillimeter measurements in the near-field of volcanic eruptions to characterize plume properties.
机译:[1]在本文中,评估了多频亚毫米波辐射计表征火山喷发近场中烟灰柱的潜力。辐射计对质量浓度和颗粒有效尺寸的敏感性最关键地取决于气溶胶高度和喷射的水蒸气浓度。还取决于温度,气溶胶形状和复数折射率。对于本研究,假定火山气溶胶是纵横比为1的随机取向的固体六边形硅酸盐。 T矩阵方法用于计算90 GHz和880 GHz之间36个频率处的气溶胶的单散射特性,并假设对数正态分布函数,得出气溶胶的整体散射特性。使用中纬度标准夏季大气和摄动的中纬度夏季大气,使用德尔塔-爱丁顿两流近似法,对辐射计对气溶胶存在的灵敏度进行量化。结果表明,如果满足以下四个条件,则在113 GHz和880 GHz之间的34个频率下,对气溶胶的灵敏度最高:(i)气溶胶层的高度应为 3 km,(ii)0.1 g m-3 <质量浓度<30 g m-3(iii)气溶胶有效尺寸De,20μm

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号