Muscle contraction during electro-muscular incapacitation: A comparison between square-wave pulses and the TASER((R)) X26 Electronic control device.

机译:肌无力时的肌肉收缩:方波脉冲和TASER X26电子控制装置之间的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Electronic control devices (including the Advanced TASER((R)) X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and swine). Pulse power, electrical pulse charge, pulse duration, and pulse repetition frequency affected muscle contraction. There was no difference in the charge required, between the square waveform and the X26 waveform, to cause approximately the same muscle-contraction response (in terms of the strength-duration curve). Thus, on the basis of these initial studies, the detailed shape of a waveform may not be important in terms of generating electro-muscular incapacitation. More detailed studies, however, may be required to thoroughly test all potential waveforms to be considered for future use in ECDs.
机译:电子控制装置(包括TASER International生产的Advanced TASER X26模型)会引起肌肉收缩,从而使个人失去能力。为了提供与未来潜在设备开发相关的信息,使用两种动物模型(青蛙和猪),将具有不同参数的单相方波的效果与X26电子控制设备的效果进行了比较。脉冲功率,电脉冲电荷,脉冲持续时间和脉冲重复频率会影响肌肉收缩。方波和X26波之间所需的电荷没有差异,以引起大约相同的肌肉收缩响应(就强度-持续时间曲线而言)。因此,根据这些初步研究,波形的详细形状在产生电肌肉无能方面可能并不重要。但是,可能需要进行更详细的研究才能彻底测试所有潜在的波形,以供将来在ECD中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号