A novel chemiluminescence(CL)system for determination of permanganate index(COD_(Mn))combined with flow injection analysis has been proposed in this study.On the basis of the chemiluminescent reaction of luminol-KMnO4 system,light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube,and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to COD_(Mn).Effects for COD_(MN)determining such as pH,concentrations and interference were investigated in detail.A detection limit of 0.3 mg/L COD_(MN)with a linear range of 0.3-200 mg/L for its theoretical COD_(MN)was obtained under the optimized experimental conditions.The relative standard deviation was 4.3% for 5.0 mg/L COD_(Mn)(n = 11).This CL flow System for determining COD_(Mn)was simple,rapid,and suitable for automatic analysis.The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method.It has been applied to determine real samples with satisfactory results.
机译:结合流动注射分析,提出了一种测定高锰酸盐指数(COD_(Mn))的化学发光体系。基于鲁米诺-KMnO4体系的化学发光反应,由鲁米诺-KMnO4引起的发光用光电倍增管检测系统,样品消解后因KMnO4的出现而引起的强度与COD_(Mn)成反比,详细研究了COD_(MN)对pH,浓度和干扰等影响的测定。在优化的实验条件下,获得了其理论COD_(MN)线性范围为0.3-200 mg / L的COD_(MN)的极限值.5.0 mg / L COD _(( Mn)(n = 11)。该用于测定COD_(Mn)的CL流动系统简单,快速且适合自动分析。通过本方法获得的数据与通过标准滴定法获得的数据相当吻合。它已被应用确定具有满意结果的真实样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号