首页> 外文期刊>Journal of Failure Analysis and Prevention >Fatigue Cracking of a 3-MW Electric Motor Shaft
【24h】

Fatigue Cracking of a 3-MW Electric Motor Shaft

机译:3兆瓦电动机轴的疲劳开裂

获取原文
获取原文并翻译 | 示例
           

摘要

After approximately fifteen months of service, cracking was detected in the journal section of a 3-MW electric motor shaft used to drive a reciprocating gas compressor. A detailed failure analysis revealed sulfide inclusion and quench crack-initiated fatigue cracks. Two crack orientations were observed, axial and angular. The axial cracks are believed to be quench cracks which initiated along sulfide stringers; the angular cracks were found to be high-cycle fatigue cracks emanating from the axial cracks. Recommendations included the use of a reduced sulfur content shaft steel (0.010 wt.% max) and a pre-service non-destructive inspection to detect the presence of quench cracks or other surface imperfections.
机译:大约服务了15个月后,在用于驱动往复式气体压缩机的3兆瓦电动机轴的轴颈部分检测到裂纹。详细的故障分析显示,硫化物夹杂物和淬火裂纹引发的疲劳裂纹。观察到两个裂纹取向,轴向和角度。轴向裂纹被认为是沿着硫化物纵梁引发的淬火裂纹。发现角形裂纹是轴向裂纹产生的高周疲劳裂纹。建议包括使用减少硫含量的轴钢(最大含量为0.010 wt。%)和使用前的非破坏性检查,以检测是否存在淬火裂纹或其他表面缺陷。