摘要

Background: We developed a monitoring system that uses total errors (TEs) to evaluate measurement of blood chemistry data from the National Health and Nutrition Survey (NHNS) and Prefectural Health and Nutrition Surveys (PHNS). Methods: Blood chemistry data from the NHNS and PHNS were analyzed by SRL, Inc., a commercial laboratory in Tokyo, Japan. Using accuracy and precision from external and internal quality controls, TEs were calculated for 14 blood chemistry items during the period 1999-2010. The acceptable range was defined as less than the upper 80% confidence limit for the median, the unacceptable range as more than twice the cut-off value of the acceptable range, and the borderline range as the interval between the acceptable and unacceptable ranges. Results: The TE upper limit for the acceptable and borderline ranges was 5.7% for total cholesterol (mg/dL), 9.9% for high-density lipoprotein cholesterol (mg/dL), 10.0% for low-density lipoprotein cholesterol (mg/dL), 10.4% for triglycerides (mg/dL), 6.6% for total protein (g/dL), 7.6% for albumin (g/dL), 10.8% for creatinine (mg/dL), 6.5% for glucose (mg/dL), 9.7% for ??-glutamyl transpeptidase (U/L), 7.7% for uric acid (mg/dL), 8.7% for urea nitrogen (mg/dL), 9.2% for aspartate aminotransferase (U/L), 9.5% for alanine aminotransferase (U/L), and 6.5% for hemoglobin A1c (%). Conclusions: This monitoring system was established to assist health professionals in evaluating the continuity and comparability of NHNS and PHNS blood chemistry data among survey years and areas and to prevent biased or incorrect conclusions. ? 2012 by the Japan Epidemiological Association.
机译:背景:我们开发了一种监视系统,该系统使用总误差(TE)来评估来自美国国家健康与营养调查(NHNS)和县健康与营养调查(PHNS)的血液化学数据的测量结果。方法:由日本东京的商业实验室SRL,Inc.分析了NHNS和PHNS的血液化学数据。利用外部和内部质量控制的准确性和精确度,计算了1999-2010年期间14种血液化学项目的TE。可接受范围定义为小于中位数的80%置信上限,不可接受范围定义为可接受范围的临界值的两倍以上,边界范围定义为可接受范围和不可接受范围之间的间隔。结果:总胆固醇(mg / dL)的TE上限和可接受范围分别为5.7%,高密度脂蛋白胆固醇(mg / dL)9.9%,低密度脂蛋白胆固醇(mg / dL)10.0% ),甘油三酸酯(mg / dL)的10.4%,总蛋白质(g / dL)的6.6%,白蛋白(g / dL)的7.6%,肌酐(mg / dL)的10.8%,葡萄糖(mg / dL的6.5%) dL),δ-谷氨酰转肽酶(U / L)的9.7%,尿酸(mg / dL)的7.7%,尿素氮(mg / dL)的8.7%,天冬氨酸转氨酶(U / L)的9.2%,丙氨酸转氨酶(U / L)为9.5%,血红蛋白A1c为6.5%(%)。结论:建立了该监测系统,以帮助卫生专业人员评估调查年份和地区之间NHNS和PHNS血液化学数据的连续性和可比性,并防止结论有偏或不正确。 ?日本流行病学协会2012年。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号