摘要

The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived from new instruments under the same experimental setup (n = 20). With the exception of F1 and F3, instruments previously used in curved canals were more susceptible to cyclic fatigue than those previously used in straight canals (p < 0.05). Separation occurred predominantly at the D10 to D12 level. For the F series, a negative correlation (p < 0.05) was observed between the number of rotations before failure and the file diameters at their separation levels. ProTaper F3 instruments are highly susceptible to cyclic fatigue failure and should be reused with caution irrespective of whether they are initially used for shaping straight or curved canals.
机译:ProTaper(Dentsply Maillefer,Ballaigues,瑞士)镍钛旋转器械对循环疲劳的抵抗力在首次用于体内直管或弯管后进行了检查。这些器械在钢模内自由旋转直至分离。在相同的实验设置(n = 20)下,将失效前的转数和分离的片段的长度与新仪器的数据进行了比较。除F1和F3外,以前用于弯管的器械比以前用于直管的器械更易遭受周期性疲劳的影响(p <0.05)。分离主要发生在D10至D12级。对于F系列,观察到故障之前的转数与分离级别的锉刀直径之间存在负相关(p <0.05)。 ProTaper F3器械极易受到周期性疲劳破坏的影响,无论最初是用于塑造直管还是弯管,都应谨慎使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号