PURPOSE: To measure changes in venous function after elimination of great saphenous vein reflux using endovenously-applied heat with a specially designed catheter. METHODS: In a prospective clinical study, 13 patients (8 women; mean age 39 years, range 25-59) with symptomatic chronic venous insufficiency were treated for reflux at the saphenofemoral junction. A radiofrequency catheter (Restore) with expandable electrodes that shrinks the vein by controlled constriction of subendothelial collagen was used to restore valve competence. Extirpation of local varicosities was performed simultaneously. Main outcome was change in venous function as measured by plethysmography (foot volumetry) and change in diameter and reflux time at the saphenofemoral junction after 6 and 12 months. RESULTS: Reflux in the greater saphenous vein was eliminated or reduced to below 0.5 seconds in all patients. The venous function was significantly improved after 6 months' follow-up, with decreased refilling rate/expelled volume related to foot volume (p=0.019). The patients were clinically improved, although only 7 (54%) were entirely free from reflux. Three (21%) patients had thrombus in the vein the day after the treatment, 2 at the treatment site and 1 at the entry site of the introducer. After 1 year, the patients are still satisfied with the results, although venous function is no longer significantly improved compared to baseline. CONCLUSIONS: It is possible to safely restore valvular competence by means of internally shrinking the vein diameter. The venous function is improved, although the vein has a tendency to increase in width with time; limited reflux reappears, with deterioration of venous function.
机译:目的:通过专门设计的导管,通过静脉内加热消除大隐静脉回流后的静脉功能变化。方法:在一项前瞻性临床研究中,对13例有症状的慢性静脉功能不全的患者(8例女性,平均年龄39岁,范围25-59)进行了for股交界处的反流治疗。具有可扩张电极的射频导管(Restore)可通过控制内皮下胶原的收缩使静脉收缩,从而恢复瓣膜功能。同时消灭局部静脉曲张。主要结果是通过体积描记法(足部容积法)测得的静脉功能变化,以及在6和12个月后隐隐股神经交界处直径和回流时间的变化。结果:在所有患者中,大隐静脉反流被消除或减少至0.5秒以下。随访6个月后,静脉功能显着改善,与足部容积相关的再填充率/排出容积降低(p = 0.019)。尽管只有7名(54%)完全没有返流,但患者的临床状况有所改善。治疗后第二天,三名(21%)患者的静脉内有血栓,在治疗部位有2名,在引入器的进入部位有1名。一年后,尽管静脉功能与基线相比不再明显改善,但患者仍对结果满意。结论:可以通过内部缩小静脉直径来安全地恢复瓣膜功能。静脉功能有改善的趋势,尽管静脉有随时间增加宽度的趋势。再次出现有限的反流,静脉功能下降。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号