Objective: To test the hypothesis that shock wave lithotripsy machines vary in their ability to fragment standardized artificial urinary calculi. Materials and Methods: An in vitro test configuration was used to fragment synthetic U-30 Gypsum (U.S. Gypsum, Chicago, IL) stones (mean length 7.10.2mm, mean diameter 6.50.07mm, mean mass 299 +/- 16mg) using the Sonolith i-sys (EDAP TMS, Vaulx-en-Velin, France), Modulith SLX F2 (Storz Medical AG, Tagerwilen, Switzerland), and Piezolith 3000 (Richard Wolf GmbH, Knittlingen, Germany) lithotripters. Gypsum stones were placed at the nominal focus and treated with 250, 500, or 1000 shocks. The residual mass following passage through a 2-mm wire mesh was measured and compared using ANOVA and the Tukey-Kramer HSD test. Results: There was no statistically significant difference between the Modulith SLX F2 and Piezolith 3000 lithotripters for 250 and 1000 shock treatments (p=0.34 and 0.31, respectively). The Piezolith 3000 demonstrated the most favorable stone mass reduction for 500 shock treatments (187.4 +/- 45.2mg). The Sonolith i-sys was found to be significantly less effective than the other lithotripters for all shockwave conditions. Furthermore, performance of the Sonolith i-sys decreased beyond a threshold generator electrode age of 6000 shocks. Conclusions: This in vitro study found considerable variability in the ability of lithotripters to fragment synthetic urinary calculi. Synthetic stones were employed to provide a repeatable means of assessing variability in fragmentation efficiency of lithotripters. The Modulith SLX F2 and Piezolith 3000 are broadly equal and resulted in greater fragmentation efficiencies than the Sonolith i-sys. The performance of the Sonolith i-sys deteriorates at 6000 shocks, before the specified lifetime of 20,000 shocks.
机译:目的:检验以下假设:冲击波碎石机碎裂标准化人工尿路结石的能力各不相同。材料和方法:使用体外测试配置将合成的U-30石膏(平均长度7.10.2mm,平均直径6.50.07mm,平均质量299 +/- 16mg)碎裂成合成U-30石膏(美国石膏,伊利诺伊州芝加哥)。 Sonolith i-sys(EDAP TMS,法国Vaulx-en-Velin),Modulith SLX F2(Storz Medical AG,瑞士Tagerwilen)和Piezolith 3000(Richard Wolf GmbH,Knittlingen,德国)碎石机。将石膏石放置在标称焦点处,并进行250、500或1000次电击处理。通过ANOVA和Tukey-Kramer HSD测试,测量并比较了通过2毫米金属丝网后的残余质量。结果:对于250和1000次电击治疗,Modulith SLX F2和Piezolith 3000碎石机之间无统计学差异(p分别为0.34和0.31)。 Piezolith 3000在500次电击处理(187.4 +/- 45.2mg)上显示出最有利的结石减少效果。发现在所有冲击波条件下,Sonolith i-sys的效率均明显低于其他碎石机。此外,Sonolith i-sys的性能下降到超过6000次电击的阈值发生器电极寿命。结论:这项体外研究发现碎石机碎裂合成尿路结石的能力存在很大差异。使用人造石来提供可重复的方法来评估碎石机碎裂效率的可变性。 Modulith SLX F2和Piezolith 3000大致相等,并且比Sonolith i-sys产生更高的碎裂效率。在指定的20,000次电击寿命之前,Sonolith i-sys的性能在6000次电击时会下降。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号