摘要

The thyratron with the cold cathode TD-50K/15 (pseudospark switch-PSS) was tested as a switch in a low inductive discharge circuit of the noiseless electrodynamic generator of shock-wave pulses of a medical lithotripter "LitURAT-UR". With the help of the given switch in therapeutic focus of a reflector steady shock-wave pulses with duration (at a level 0.5 peak values) from 0.2 to 0.5 /spl mu/s with amplitude up to 100 MPa were obtained. The transfer of energy from a radiator to therapeutic focus went through a "water" pillow. A mode of operation was: anode voltage 10 kV, switched current of the discharge 50 kA, switched capacity 2 /spl mu/F. The basic requirements to a switch were reliability and stability of operation-absence of uncontrollable breakdowns and misfiring of an ignition, and also a current quenching. Design features of a lithotripter and PSS are presented.
机译:将带有冷阴极TD-50K / 15的晶闸管(伪火花开关-PSS)作为医用碎石机“ LitURAT-UR”的冲击波脉冲的无噪声电动发生器的低电感放电电路中的开关进行了测试。在给定的反射器治疗聚焦开关的帮助下,可获得稳定的冲击波脉冲,其持续时间(水平为0.5峰值)为0.2至0.5 / spl mu / s,振幅最高为100 MPa。能量从散热器转移到治疗焦点的过程是通过“水”枕进行的。操作模式为:阳极电压10 kV,放电的开关电流50 kA,开关容量2 / spl mu / F。开关的基本要求是操作的可靠性和稳定性-不可控制的击穿和点火失火以及电流淬火。介绍了碎石机和PSS的设计特征。