BACKGROUND AND OBJECTIVE: Based upon the thermal relaxation time of the hair follicle (10-50 ms), most lasers and light devices use relatively long pulse widths for hair removal. This study was conducted to evaluate a shorter pulsed, 0.65 ms Nd:YAG laser for hair removal. METHODS: One half of each axilla of six female participants was treated and the other half was monitored as a control. The treatment sites were treated with a fluence of either 21 J/cm(2) or 36 J/cm(2) using an Nd:YAG laser with a wavelength of 1064 nm and a pulse duration of 0.65 ms. A manual hair count was done before treatment and at each follow-up visit. RESULTS: Four months after four monthly treatments, the hair reduction was graded as 5 (75-100% reduction) on the high fluence side and 4 on the low fluence side (50-75% reduction) by individuals and investigators. The average hair count 4 months after four treatments in the sites treated with a high fluence went from 114 to 28 (76% reduction) and in the low fluence areas from 135to 38 (72% reduction). CONCLUSION: This well-controlled study shows that a 0.65 ms Nd:YAG laser is effective and safe for hair removal.
机译:背景与目的:基于毛囊的热弛豫时间(10-50毫秒),大多数激光和照明设备使用相对较长的脉冲宽度进行脱毛。进行这项研究是为了评估较短脉冲的0.65 ms Nd:YAG激光用于脱毛。方法:对六名女性参与者的每个腋窝进行了一半的治疗,另一半作为对照进行了监测。使用波长为1064 nm,脉冲持续时间为0.65 ms的Nd:YAG激光以21 J / cm(2)或36 J / cm(2)的通量对治疗部位进行治疗。在治疗前和每次随访时都进行了人工毛发计数。结果:个人和研究人员在进行了四个月的治疗后四个月,在高通量方面的毛发减少等级为5(减少75-100%),在低通量方面的毛发减少等级为4(减少50-75%)。高通量治疗部位的四个处理后四个月的平均头发数从114增至28(减少76%),低通量区域从135至38(减少72%)。结论:这项控制良好的研究表明,0.65 ms Nd:YAG激光可有效,安全地脱毛。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号