A Practice Quality Improvement Project: Reducing Dose of Routine Chest CT Imaging in a Busy Clinical Practice

机译:实践质量改进项目:在繁忙的临床实践中减少常规胸部CT成像的剂量

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this report is to describe our experience with the implementation of a practice quality improvement (PQI) project in thoracic imaging as part of the American Board of Radiology Maintenance of Certification process. The goal of this PQI project was to reduce the effective radiation dose of routine chest CT imaging in a busy clinical practice by employing the iDose(4) (Philips Healthcare) iterative reconstruction technique. The dose reduction strategy was implemented in a stepwise process on a single 64-slice CT scanner with a volume of 1141 chest CT scans during the year. In the first annual quarter, a baseline effective dose was established using the standard filtered back projection (FBP) algorithm protocol and standard parameters such as kVp and mAs. The iDose(4) technique was then applied in the second and third annual quarters while keeping all other parameters unchanged. In the fourth quarter, a reduction in kVp was also implemented. Throughout the process, the images were continually evaluated to assure that the image quality was comparable to the standard protocol from multiple other scanners. Utilizing a stepwise approach, the effective radiation dose was reduced by 23.62 and 43.63 % in quarters two and four, respectively, compared to our initial standard protocol with no perceived difference in diagnostic quality. This practice quality improvement project demonstrated a significant reduction in the effective radiation dose of thoracic CT scans in a busy clinical practice.
机译:本报告的目的是描述我们在实施胸部成像中的实践质量改进(PQI)项目方面的经验,这是美国放射学维护认证委员会程序的一部分。该PQI项目的目标是通过采用iDose(4)(Philips Healthcare)迭代重建技术来减少繁忙的临床实践中常规胸部CT成像的有效辐射剂量。减少剂量的策略是在一台64层CT扫描仪上逐步进行的,该扫描仪在一年中进行了1141例胸部CT扫描。在第一季度,使用标准过滤反投影(FBP)算法协议和kVp和mAs等标准参数确定基线有效剂量。然后在第二个和第三个年度季度应用iDose(4)技术,同时保持所有其他参数不变。在第四季度,还降低了kVp。在整个过程中,不断对图像进行评估,以确保图像质量与来自其他多个扫描仪的标准协议相当。与我们的初始标准方案相比,采用逐步方法,与我们最初的标准方案相比,第二季度和第四季度的有效辐射剂量分别减少了23.62%和43.63%,而诊断质量没有明显的差异。该实践质量改进项目表明,在繁忙的临床实践中,胸部CT扫描的有效辐射剂量显着降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号