首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Development and analytical performance evaluation of an automated chemiluminescent immunoassay for pro-gastrin releasing peptide (ProGRP).
【24h】

Development and analytical performance evaluation of an automated chemiluminescent immunoassay for pro-gastrin releasing peptide (ProGRP).

机译:胃泌素释放肽(ProGRP)自动化学发光免疫测定的开发和分析性能评估。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Pro-gastrin releasing peptide (ProGRP) concentrations in blood play an important role in the diagnosis and treatment of patients with small cell lung cancer (SCLC). The automated quantitative ARCHITECT ProGRP assay was developed to aid in the differential diagnosis and in the management of SCLC. The purpose of this study was to evaluate the analytical performance of this chemiluminescent microparticle immunoassay at multiple sites. METHODS: ARCHITECT ProGRP measures ProGRP using a two-step sandwich using monoclonal anti-ProGRP antibodies coated on paramagnetic microparticles and labeled with acridinium. Analytical performance of the assay was evaluated at four sites: Abbott Japan, Denka Seiken, the Johns Hopkins University, and the University of Munich. RESULTS: Total precision (%CV) for nine analyte concentrations was between 2.2 and 5.7. The analytical sensitivity of the assay was between 0.20 pg/mL and 0.88 pg/mL. The functional sensitivity at 20% CV was between 0.66 pg/mL and 1.73 pg/mL. The assay was linear up to 50,000 pg/mL using a 1:10 autodilution protocol. The calibration curve was stable for 30 days. Comparison with the Fujirebio microtiter plate enzyme-linked immunosorbent assay (EIA) ProGRP assay gave a slope of 0.93 and a correlation coefficient (r) of 0.99. CONCLUSIONS: These results demonstrate that the ARCHITECT ProGRP assay has excellent sensitivity, precision, and correlation to a reference method. This assay provides a convenient automated method for ProGRP measurement in serum and plasma in hospitals and clinical laboratories.
机译:背景:血液中的胃泌素释放肽(ProGRP)浓度在小细胞肺癌(SCLC)患者的诊断和治疗中起着重要作用。开发了自动定量ARCHITECT ProGRP测定法,以帮助鉴别诊断和管理SCLC。这项研究的目的是评估该化学发光微粒免疫测定法在多个位置的分析性能。方法:ARCHITECT ProGRP使用两步法夹心法测量ProGRP,该程序采用包被在顺磁微粒上并用a啶标记的单克隆抗ProGRP抗体。在四个地点对测定的分析性能进行了评估:日本雅培,Denka Seiken,约翰霍普金斯大学和慕尼黑大学。结果:九种分析物浓度的总精密度(%CV)在2.2至5.7之间。该测定的分析灵敏度在0.20 pg / mL至0.88 pg / mL之间。 20%CV时的功能灵敏度在0.66 pg / mL和1.73 pg / mL之间。使用1:10自动稀释方案,测定线性高达50,000 pg / mL。校准曲线可稳定30天。与Fujirebio微量滴定板酶联免疫吸附测定(EIA)进行比较,ProGRP测定的斜率为0.93,相关系数(r)为0.99。结论:这些结果表明,ARCHITECT ProGRP测定法具有出色的灵敏度,精密度以及与参考方法的相关性。该测定法为医院和临床实验室中的血清和血浆中ProGRP测量提供了一种方便的自动化方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号