...
首页> 外文期刊>Journal of clinical densitometry >Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images
【24h】

Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images

机译:射线照相和双能X射线吸收仪图像对骨关节炎的Kellgren-Lawrence分级的重现性和诊断准确性

获取原文
获取原文并翻译 | 示例
           

摘要

Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.
机译:现在,现代双能X射线吸收仪(DXA)扫描仪在图像质量方面取得了进步,现在可以在低辐射剂量下获得接近射线照相的高质量图像。这为使用DXA扫描仪研究其他肌肉骨骼疾病(例如骨关节炎)开辟了潜在的新应用,通常通过X光片的目视评估对其进行研究。骨质疏松症和骨关节炎共同是两种最常见的肌肉骨骼疾病,两者都主要影响老年人。这项研究的目的是确定DXA图像的Kellgren-Lawrence分级是否可以像放射照片一样有效地对髋骨关节炎进行分级。曾参加近期骨盆X线检查的人使用GE Healthcare iDXA扫描仪进行了髋关节DXA检查(25人中有50髋)。三名观察员为每张图像分配了Kellgren-Lawrence评分,并且至少每隔1周重复一次评分。使用二次加权卡伯(QWK)计算X射线照片和DXA图像的观察者内和观察者间可靠性。人们在12个月后被召回,并在彼此相隔2周内进行了X射线照片和DXA扫描,重复了测试。髋关节DXA的观察者内可重复性达到了QWK范围为0.88-0.95,观察者间的可重复性为0.85-0.88,与髋部X射线照片中的QWK相似。受试者匹配的X射线照片与iDXA图像之间的观察者内部可靠性显示QWK在0.80至0.88之间。在本研究中,使用DXA对髋骨关节炎分级的可重复性与X线照片可比,并且与以前在文献中发表的可重复性评分相似。鉴于较低的放射剂量和同时检查骨质疏松症的机会,DXA为骨关节炎提供了一种有吸引力的影像学选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号