首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Development and validation of a chiral liquid chromatography method for the determination of MP 3950 enantiomers, a high selective 5-HT4 receptor agonist, in rat plasma and its application to stereoselective pharmacokinetic study
【24h】

Development and validation of a chiral liquid chromatography method for the determination of MP 3950 enantiomers, a high selective 5-HT4 receptor agonist, in rat plasma and its application to stereoselective pharmacokinetic study

机译:手性液相色谱法测定大鼠血浆中高选择性5-HT4受体激动剂MP 3950对映体的开发与验证,及其在立体选择性药代动力学研究中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

MP 3950 is an active metabolite of mosapride which exhibits high 5-HT4 receptor agonistic effect. The present paper describes an enantioselective chiral HPLC method for separation and quantification of MP 3950 enantiomers in rat plasma. The plasma samples were prepared by liquid-liquid extraction with ethyl acetate and the baseline chromatographic separation was achieved on a Chiralcel OJ-H column with a mobile phase consisting n-hexane/ethanol/methanol/diethylamine (85:5:10:0.4, v/v/v/v) at the flow rate of 1.0 mL/min. The ultraviolet detection was performed at 276 nm. The calibration curve was linear in the range from 0.100 to 5.00 mu g/mL with the lower limit of quantification of 0.100 mu g/mL for each enantiomer. The intra- and inter-day precisions were not more than 14.7%. The accuracy was from -6.4% to 14.0%. The validated method was successfully applied to chiral inversion and stereoselective pharmacokinetic study in rats after oral administration of MP 3950 racemate. The results indicated that no stereochemical inversion was occurred in rats. And the plasma concentrations and area under plasma concentration-time curve of (S)-MP 3950 were all significantly higher than those of (R)-MP 3950 in both male and female rats, which indicated that the disposition of MP 3950 in rats might be stereoselective. (C) 2016 Elsevier B.V. All rights reserved.
机译:MP 3950是莫沙必利的活性代谢产物,具有较高的5-HT4受体激动作用。本文描述了一种对映选择性手性HPLC方法,用于分离和定量大鼠血浆中的MP 3950对映异构体。通过用乙酸乙酯进行液-液萃取制备血浆样品,并在Chiralcel OJ-H色谱柱上进行基线色谱分离,色谱柱的流动相为正己烷/乙醇/甲醇/二乙胺(85:5:10:0.4, v / v / v / v),流速为1.0 mL / min。紫外线检测在276 nm处进行。校准曲线在0.100至5.00μg / mL范围内呈线性,每种对映体的定量下限为0.100μg / mL。日内和日间精度不超过14.7%。准确度从-6.4%到14.0%。经验证的方法已成功应用于大鼠口服MP 3950外消旋体后的手性转化和立体选择性药代动力学研究。结果表明在大鼠中没有发生立体化学倒置。雌雄大鼠中(S)-MP 3950的血浆浓度和血浆浓度-时间曲线下面积均明显高于(R)-MP 3950,这表明MP 3950在大鼠体内的处置可能具有立体选择性。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号