首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Study of the selectivity of inorganic anions in hydro-organic solvents using indirect capillary electrophoresis
【24h】

Study of the selectivity of inorganic anions in hydro-organic solvents using indirect capillary electrophoresis

机译:间接毛细管电泳法研究有机溶剂中无机阴离子的选择性

获取原文
获取原文并翻译 | 示例
           

摘要

In capillary electrophoresis (CE) analysis of small inorganic anions, the ability to control the electroosmotic flow (EOF) and the ability to alter the electrophoretic mobility of the ions are essential to improve resolution and separation speed. In this work, a CE method for separation of small inorganic anions using indirect detection in mixed methanol/water buffers is presented. The suitability of different UV absorbing probes commonly used for indirect detection including chromate, iodide, phthalate, benzoate, trimellitate, and pyromellitate, in mixed methanol/water buffers is examined. The effect of the electrolyte buffer system, including the pH, buffer concentration and the organic solvent on the electrophoretic mobility of the probes and analytes are also investigated. The EOF was reversed using cationic surfactant, cetyltrimethylammonium bromide (CTAB) so ions were separated under co-EOF mode. The organic solvent alters the electrophoretic mobility of the probes and the analytes differently and hence choice of the appropriate probe is essential to achieve high degree of detection sensitivity. Separations of six anions in less than 2.5 min were accomplished in buffers containing up to 30% MeOH. Adjustment of the methanol content helps to improve the selectivity and resolution of inorganic anions. Limit of detection, reproducibility and application of the method for quantification of anions in water samples will also be discussed. (c) 2004 Elsevier B.V. All rights reserved.
机译:在小的无机阴离子的毛细管电泳(CE)分析中,控制电渗流(EOF)的能力和改变离子的电泳迁移率的能力对于提高分离度和分离速度至关重要。在这项工作中,提出了一种在混合的甲醇/水缓冲液中使用间接检测方法分离小的无机阴离子的CE方法。检查了通常用于间接检测的不同紫外线吸收探针在混合的甲醇/水缓冲液中的适用性,包括铬酸盐,碘化物,邻苯二甲酸盐,苯甲酸盐,偏苯三酸酯和均苯四酸酯。还研究了电解质缓冲液系统(包括pH,缓冲液浓度和有机溶剂)对探针和分析物的电泳迁移率的影响。使用阳离子表面活性剂十六烷基三甲基溴化铵(CTAB)逆转EOF,以便在co-EOF模式下分离离子。有机溶剂会不同地改变探针和分析物的电泳迁移率,因此选择合适的探针对于实现高度的检测灵敏度至关重要。在最多含30%MeOH的缓冲液中,在不到2.5分钟的时间内完成了六个阴离子的分离。调节甲醇含量有助于改善无机阴离子的选择性和分离度。还讨论了水样品中阴离子的检测限,重现性和应用方法。 (c)2004 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号