首页> 外文期刊>Journal of clinical laboratory analysis. >Present Status of the Standardization of HDL-C, LDL-C, and TG Measurement Values Available in Japan
【24h】

Present Status of the Standardization of HDL-C, LDL-C, and TG Measurement Values Available in Japan

机译:日本提供的HDL-C,LDL-C和TG测量值标准化的现状

获取原文
获取原文并翻译 | 示例

摘要

Background: Control sera used as evaluation samples in external quality control of HDL-C and LDL-C sometimes show disparities in results between direct methods differing in reaction principles. As a result, the present standardization status is unclear. In 2008, we investigated the present status of standardization of HDL-C, LDL-C, and TG measurement values available in Japan. Subjects and Methods: To evaluate accuracy, refrigerated fresh human serum pools used as samples were analyzed irrespective of the manufacturer's method. To evaluate precision, a questionnaire survey regarding the internal quality control status at each institution was carried out. As evaluation criteria, the permissible limits of error of BA and CVA based on JSCC proposals, and the accuracy and imprecision criterion NCEP proposals were used. Results: There were 70 participating institutions for HDL-C, 65 for LDL-C, and 71 for TG. TG values from the institutions showed 83.1-91.5% for both the JSCC BA range and the NCEP criterion range. HDL-C values within the JSCC BA range were 81.4-82.6% and within the NCEP criterion range the value was 98.6%. Similarly, LDL-C values within the JSCC BA range were 89.2% and within the NCEP criterion range the value were 81.5-83.1%, respectively. Concerning precision, a questionnaire regarding internal quality control of each institution was completed. More than 90% of the institutions showed values within the CVA range proposed by the JSCC for all of HDL-C, LDL-C, and TG. Conclusion: Standardization of lipid assays used for metabolic syndrome-based health checkups has been mostly achieved.
机译:背景:在HDL-C和LDL-C的外部质量控制中,用作评估样品的对照血清有时会在反应原理不同的直接方法之间显示出差异。结果,目前的标准化状态尚不清楚。在2008年,我们调查了日本提供的HDL-C,LDL-C和TG测量值标准化的现状。对象和方法:为了评估准确性,无论制造商的方法如何,都对用作样品的冷藏新鲜人血清池进行了分析。为了评估准确性,对每个机构的内部质量控制状况进行了问卷调查。作为评估标准,使用了基于JSCC提议的BA和CVA的允许误差范围,以及NCEP提议的准确性和不精确性标准。结果:HDL-C的参与机构有70个,LDL-C的参与机构有65个,TG的参与机构有71个。这些机构的TG值对于JSCC BA范围和NCEP标准范围均显示为83.1-91.5%。 JSCC BA范围内的HDL-C值为81.4-82.6%,NCEP标准范围内的HDL-C值为98.6%。同样,JSCC BA范围内的LDL-C值分别为89.2%和NCEP标准范围内的LDL-C值分别为81.5-83.1%。关于精度,已完成了有关每个机构内部质量控制的调查问卷。超过90%的机构显示JSCC针对所有HDL-C,LDL-C和TG的CVA值均在此范围内。结论:用于基于代谢综合征的健康检查的脂质测定法的标准化已基本实现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号