首页> 外文期刊>Journal of computer assisted tomography >Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation.
【24h】

Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation.

机译:通过使用低剂量造影剂和盐水追踪器的64排螺旋计算机断层扫描进行冠状动脉血管造影:总注射量对血管衰减的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: To assess the influence of total injection volume on thoracic great vessels and coronary arteries enhancement in 64-detector row computed tomography (CT) coronary angiography using low dose of contrast material. METHODS: Sixty patients underwent cardiac CT (64 x 0.5 mm, 0.4 rot/s) using 40 mL of contrast material (350 mg of Iodine per milliliter) in 30 patients and 50 mL in 30 patients. Computed tomography densities (Hounsfield units) in ascending aorta, descending aorta, and main pulmonary artery were measured at every second with the time of CT data acquisition recorded in each reconstructed image. Computed tomography densities of proximal and distal coronary arteries were also measured. Differences in CT densities between 40 and 50 mL contrast material were assessed with the Student t test. In addition, the relation between the injection volume (mL) of contrast material per kilogram body weight and contrast enhancement in coronary arteries was studied. RESULTS: The average attenuations inthe ascending and descending aorta and coronary arteries were significantly lower in 40-mL group than in 50-mL group (<0.05). In addition, the average attenuations in the pulmonary artery were significantly lower in 40-mL group than 50-mL group (<0.01). Every patient with the total injection volume of more than 0.9 mL/kg body weight showed a contrast enhancement more than 250 Hounsfield units. CONCLUSIONS: The reduction of total injection volume lowered the enhancement of thoracic great vessels and coronary arteries in 64-detector row cardiac CT. The injection volume of at least 0.9 mL/kg body weight was necessary for a steady contrast enhancement in coronary arteries.
机译:目的:在低剂量造影剂的64排行计算机断层扫描(CT)冠状动脉造影中,评估总注射量对胸大血管和冠状动脉增强的影响。方法:60例患者接受心脏CT检查(64 x 0.5 mm,0.4 rot / s),其中40例造影剂(350毫克碘/毫升)在30例患者中接受50毫升造影剂。每秒测量升主动脉,降主动脉和主要肺动脉的计算机断层扫描密度(Hounsfield单位),并在每个重建图像中记录CT数据的时间。还测量了近端和远端冠状动脉的计算机断层扫描密度。使用Student t检验评估40毫升和50毫升造影剂之间的CT密度差异。另外,研究了每千克体重的造影剂注射量(mL)与冠状动脉造影剂增强之间的关系。结果:40 mL组的升主动脉和降主动脉和冠状动脉的平均衰减显着低于50 mL组(<0.05)。此外,40 mL组的肺动脉平均衰减明显低于50 mL组(<0.01)。总注射量超过0.9 mL / kg体重的每位患者显示超过250个Hounsfield单位的对比度增强。结论:总注射量的减少降低了64排行心脏CT的胸大血管和冠状动脉的增强。至少要有0.9 mL / kg体重的注射量才能稳定增强冠状动脉的造影剂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号