首页> 外文期刊>Journal of cataract and refractive surgery >Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power Randomized multicenter clinical study.
【24h】

Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power Randomized multicenter clinical study.

机译:双侧植入切趾衍射非球面丙烯酸人工晶状体后屈光度数为+3.0或+4.0的功能结果随机多中心临床研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses (IOLs) with a +3.0 or +4.0 diopter (D) addition (add) power. SETTING: Twelve study centers in the United States. METHODS: This randomized patient-masked parallel-group 6-month follow-up study comprised patients having bilateral cataract extraction with implantation of an AcrySof IQ ReSTOR SN6AD3 IOL with a +4.0 D add power (+4.0 D group) or an AcrySof IQ ReSTOR SN6AD1 IOL with a +3.0 D add power (+3.0 D group) (both IOLs, Alcon, Inc.). Visual acuity, defocus testing, patient-reported outcomes, and safety measures were assessed. RESULTS: Of the 279 patients, 141 were in the +3.0 D group and 138 were in the +4.0 D group. Binocular distance-corrected intermediate visual acuity was statistically significantly better in the +3.0 D group than in the +4.0 D group (P<.0001); there was no difference in binocular near or distance visual acuity. There were no statistically significant differences in visual disturbances between the 2 groups. Patients in both groups reported excellent overall spectacle independence, near visual function, and satisfaction with the IOLs. CONCLUSIONS: Intermediate vision at a mean reading distance of approximately 40 cm was better with the aspheric IOL with a +3.0 D add than with the aspheric IOL with a +4.0 D add, as shown by the near peak in the mean binocular defocus curve; near and distance acuity were similar between the 2 IOLs. Patients reported excellent overall quality of vision, spectacle independence, and satisfaction.
机译:目的:评估双侧切趾的非球面丙烯酸人工晶状体(IOL)的屈光度数为+3.0或+4.0屈光度(D)。地点:美国的十二个学习中心。方法:该随机分组的患者掩盖的平行组为期6个月的随访研究包括双侧白内障摘除术患者,植入了+4.0 D增加力的AcrySof IQ ReSTOR SN6AD3 IOL(+4.0 D组)或AcrySof IQ ReSTOR SN6AD1 IOL,具有+3.0 D附加功率(+3.0 D组)(均为IOL,Alcon,Inc.)。评估了视力,散焦测试,患者报告的结果和安全措施。结果:279例患者中,+ 3.0 D组141例,+ 4.0 D组138例。在统计学上,+ 3.0 D组的双眼距离校正中间视力明显好于+4.0 D组(P <.0001)。双眼近视或远视视力无差异。两组之间的视觉障碍没有统计学上的显着差异。两组患者均报告其出色的整体眼镜独立性,近视觉功能和对IOL的满意度。结论:平均双眼散焦曲线中的近峰值显示,+ 3.0 D的非球面IOL优于+4.0 D的非球面IOL,其平均阅读距离约为40 cm。两个IOL之间的近视和距离敏锐度相似。患者报告其总体视觉质量,眼镜独立性和满意度极佳。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号