首页> 外文期刊>Journal of cataract and refractive surgery >Comparison of photochromic, yellow, and clear intraocular lenses in human eyes under photopic and mesopic lighting conditions.
【24h】

Comparison of photochromic, yellow, and clear intraocular lenses in human eyes under photopic and mesopic lighting conditions.

机译:在明视和中视照明条件下人眼中光致变色,黄色和透明的人工晶状体的比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To evaluate the results of the first blue light-filtering photochromic intraocular lens (IOL) and compare them with those of a regular yellow blue light-filtering IOL and a clear ultraviolet-filtering IOL in human eyes under various lighting conditions. SETTING: Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China. DESIGN: Prospective comparative clinical study. METHODS: This study evaluated eyes that had implantation of 1 of the following 3 IOLs: photochromic Aurium Matrix acrylic, model 400; yellow AF-1 (UY); or clear MC611MI. All eyes were followed for 3 months. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, contrast vision (lighting 400 lux, 30 lux, 5 lux), contrast sensitivity, color vision (Farnsworth-Munsell 100-hue test under 400 lux, 30 lux), and patient questionnaire responses were evaluated. RESULTS: The photochromic IOL group comprised 39 eyes; the yellow IOL group, 41 eyes; and the clear IOL group, 38 eyes. There were no significant differences between the 3 IOLs in UDVA, CDVA, contrast sensitivity, or questionnaire responses. The photochromic group had significantly better color vision than the yellow IOL group at 30 lux and better contrast vision at 5% contrast (P < .05); however, there were no significant differences between the photochromic IOL group and the clear IOL group (P > .05). CONCLUSION: The photochromic blue light-filtering IOL performed as well as the yellow and clear IOLs under photopic conditions. Under mesopic conditions, the yellow IOL gave poor color vision and contrast sensitivity.
机译:目的:评估在不同光照条件下人眼中第一个滤蓝光的光致变色人工晶状体(IOL)的结果,并将其与普通的滤蓝光的IOL和透明的滤光的IOL进行比较。单位:首都医科大学附属北京同仁医院北京同仁眼科中心;北京市眼科学与视觉科学重点实验室,北京。设计:前瞻性比较临床研究。方法:本研究评估了植入以下3种IOL中的1种的眼睛:光致变色Aurium Matrix丙烯酸酯,型号400;黄色AF-1(UY);或清除MC611MI。随访3个月。未经矫正(UDVA)和矫正(CDVA)的远视力,对比视觉(照明400 lux,30 lux,5 lux),对比敏感度,色觉(Farnsworth-Munsell 100色相测试在400 lux,30 lux下),以及评估了患者问卷调查的回答。结果:光致变色IOL组有39只眼。黄色的IOL组41眼;清晰的IOL组38眼。 UDVA,CDVA,对比敏感度或问卷回答中的3种IOL之间无显着差异。光致变色组在30 lux时的色觉明显优于黄色IOL组,在5%对比度下的对比度更好(P <.05)。但是,光致变色IOL组与透明IOL组之间无显着差异(P> .05)。结论:在可见光条件下,光致变色蓝色滤光IOL的性能与黄色和透明IOL相同。在介观条件下,黄色IOL的色觉和对比度敏感性差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号