...
首页> 外文期刊>Journal of cataract and refractive surgery >Microincision multifocal intraocular lens with and without a capsular tension ring: optical quality and clinical outcomes.
【24h】

Microincision multifocal intraocular lens with and without a capsular tension ring: optical quality and clinical outcomes.

机译:具有和不具有囊张力环的微切口多焦点人工晶状体:光学质量和临床结果。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To study the effect of a capsular tension ring (CTR) on the visual, refractive, and intraocular optical quality of a multifocal intraocular lens (IOL) with diffractive asymmetrical light distribution. SETTING: Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. METHODS: An Acri.Lisa 366D IOL was implanted without CTR implantation in 54 eyes (Group 1) or with Acri.Ring BR 11 CTR implantation in 40 eyes (Group 2). Intraocular optical quality in vivo was characterized by the difference between the postoperative total and corneal optical aberrations. Visual, refractive, and intraocular optical outcomes were evaluated 3 months postoperatively. Main outcome measures included postoperative residual refraction, uncorrected and corrected far and near visual acuities, intraocular aberrations, the Strehl ratio, and the modulation transfer function (MTF). RESULTS: The postoperative means in Group 1 were spherical equivalent, 0.31 +/- 0.45 diopters (D); uncorrected distance acuity, 0.79 +/- 0.19; best corrected distance acuity, 0.95 +/- 0.11; uncorrected near acuity, 0.77 +/- 0.21; best corrected near acuity, 0.89 +/- 0.14; best distance-corrected acuity, 0.90 +/- 0.12. The Group 2 means were -0.18 +/- 0.60 D, 0.74 +/- 0.23, 0.98 +/- 0.07, 0.72 +/- 0.22, 0.86 +/- 0.14, and 0.86 +/- 0.14, respectively. Group 2 had a statistically significant reduction in intraocular aberrations and a significant increase in MTF values and Strehl ratios compared with Group 1. CONCLUSION: Combined use of the CTR and Acri.Lisa 366D IOL provided good efficacy, predictability, and safety and increased the intraocular optical performance, suggesting better IOL stability.
机译:目的:研究荚膜张力环(CTR)对具有衍射不对称光分布的多焦点人工晶状体(IOL)的视觉,屈光和眼内光学质量的影响。地点:西班牙阿利坎特,阿利坎特市立圣母学院。方法:Acri.Lisa 366D IOL植入无CTR植入54眼(第1组)或Acri.Ring BR 11 CTR植入40眼(第2组)。体内眼内光学质量的特征在于术后总光学像差和角膜光学像差之间的差异。术后3个月评估视觉,屈光和眼内光学结果。主要结局指标包括术后残余屈光度,未矫正和矫正远近视力,眼内像差,斯特列尔比和调制传递函数(MTF)。结果:第1组的术后平均球度为0.31 +/- 0.45屈光度(D)。未经校正的距离敏锐度,0.79 +/- 0.19;最佳矫正距离视力,0.95 +/- 0.11;未经校正的近视度数,0.77 +/- 0.21;最佳矫正近视度,0.89 +/- 0.14;最佳距离校正敏锐度,0.90 +/- 0.12。第2组平均值分别为-0.18 +/- 0.60 D,0.74 +/- 0.23、0.98 +/- 0.07、0.72 +/- 0.22、0.86 +/- 0.14和0.86 +/- 0.14。与第1组相比,第2组的眼内像差有统计学上的显着降低,MTF值和Strehl比有显着增加。结论:CTR和Acri.Lisa 366D IOL的联合使用可提供良好的疗效,可预测性和安全性,并增加了眼内光学性能,表明更好的IOL稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号