Personalized correction of spherical aberration in cataract surgery.

机译:白内障手术中球差的个性化校正。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To compare contrast sensitivity after phacoemulsification with implantation of the Tecnis intraocular lens (IOL) between patients with a selected preoperative corneal spherical aberration and patients without a selected amount of aberration. SETTING: Private practice, St. Catharines, Ontario, Canada. METHODS: Thirty-three cataract patients were divided into 2 groups. The first group (n = 13) included consecutive patients with a spherical aberration of at least +0.33 microm measured with the Oculus Easygraph. Consecutive patients meeting the inclusion criteria (n = 20) were included in the second group. All patients had phacoemulsification with implantation of the Tecnis IOL. After 3 to 5 weeks, contrast sensitivity was measured by sinusoidal grating charts for distance under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions with optical correction in place. Five standard spatial frequencies were tested. RESULTS: All surgical procedures and postoperative courses were uneventful. The IOLs were in the bag without decentration or tilt. The mean preoperative spherical aberration was +0.370 microm +/- 0.024 (SD) in the first group and +0.291 +/- 0.081 microm in the second group (P = .0010). Patients in the first group had better contrast sensitivity than those in the second group. Statistically significant differences were detected at spatial frequencies of 6.0 cycles per degree (cpd) and 12 cpd under photopic conditions (P = .0267 and P = .0215, respectively) and mesopic conditions (P = .0356 and P = .0217, respectively). CONCLUSIONS: The Tecnis IOL has a negative spherical aberration of -0.27 microm. Targeting for a postoperative mean residual spherical aberration of approximately +0.10 microm by selecting patients according to their preoperative spherical aberration resulted in better contrast sensitivity.
机译:目的:比较超声乳化后植入Tecnis人工晶状体(IOL)的对比敏感度,这些患者在术前选择的角膜球差和没有选择的像差量的患者之间。地点:加拿大安大略省圣凯瑟琳斯的私人诊所。方法:将33例白内障患者分为两组。第一组(n = 13)包括使用Oculus Easygraph测量的球差至少为+0.33微米的连续患者。符合入组标准(n = 20)的连续患者被纳入第二组。所有患者均植入Tecnis IOL进行超声乳化。 3至5周后,在正视(85 cd / m2)和中视(3 cd / m2)的条件下,通过正弦光栅图测量距离的对比灵敏度,并进行光学校正。测试了五个标准空间频率。结果:所有手术程序和术后过程均顺利进行。 IOL装在袋子中,没有偏心或倾斜。第一组的平均术前球差为+0.370微米+/- 0.024微米(SD),第二组的平均术前球差为+0.291 +/- 0.081微米(P = 0.0010)。与第二组相比,第一组患者具有更好的对比敏感度。在光度条件下(分别为P = .0267和P = .0215)和中观条件下(分别为P = .0356和P = .0217),在每度6.0周期(cpd)和12 cpd的空间频率下检测到统计学显着差异。 )。结论:Tecnis IOL的负球差为-0.27微米。通过根据患者术前球差选择患者,确定术后平均残余球差约为+0.10微米,从而获得更好的对比敏感度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号