首页> 外文期刊>Journal of cataract and refractive surgery >Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation.
【24h】

Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation.

机译:初次和次次巩膜缝合后房型人工晶状体植入后的倾斜和偏心。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate tilt and decentration after primary and secondary implantation of transsclerally sutured posterior chamber intraocular lenses (PC IOLs). SETTING: Dokuz Eylul University Medical School, Department of Ophthalmology, Izmir, Turkey. METHODS: Fifty-six consecutive eyes of 53 patients who had implantation of transsclerally sutured PC IOLs were prospectively included in the study. Intraocular lens tilt and decentration after primary (14 eyes) and secondary (42 eyes) implantation were compared quantitatively using Purkinje images. RESULTS: The mean IOL tilt was 6.09 degrees +/- 3.80 (SD) in all eyes, 5.71 +/- 3.41 degrees in the primary implantation group, and 6.22 +/- 3.94 degrees in the secondary implantation group. The mean IOL decentration was 0.67 +/- 0.43 mm (range 0 to 2.5 mm), 0.59 +/- 0.38 mm, and 0.69 +/- 0.45 mm, respectively. There were no statistically significant differences between the primary and secondary implantation groups in decentration or tilt. Decentration greater than 1.0 mm was present in 7 eyes (16.7%) after secondary implantation and in 1 eye (7.1%) after primary implantation. Tilting of more than 10 degrees was present in 7 eyes (16.7%) and 2 eyes (14.2%), respectively. There were no statistically significant differences between the 2 groups in decentration greater than 1.0 mm (chi square = 0.194, P =.834) or in tilting greater than 10 degrees (chi square = 0.834, P =.659). CONCLUSIONS: Clinically significant IOL tilt or decentration was rare after transscleral implantation. There were no differences in tilt or decentration between primary and secondary implantation.
机译:目的:评估经巩膜缝合后房型人工晶状体(PC IOL)初次和二次植入后的倾斜度和偏心度。地点:土耳其伊兹密尔Dokuz Eylul大学医学院眼科。方法:前瞻性地纳入了53例经巩膜缝合PC IOL植入的患者的56只连续眼睛。使用浦肯野图像定量比较原发(14眼)和继发(42眼)植入后人工晶状体的倾斜度和偏心度。结果:所有人工眼的平均IOL倾斜度均为6.09度+/- 3.80(SD),主要植入组的平均IOL倾斜度为5.71 +/- 3.41度,而次要植入组的平均IOL倾斜度为6.22 +/- 3.94度。 IOL平均偏心分别为0.67 +/- 0.43毫米(范围为0至2.5毫米),0.59 +/- 0.38毫米和0.69 +/- 0.45毫米。主要植入组和次要植入组在偏心或倾斜方面没有统计学上的显着差异。二次植入后7只眼(16.7%)和一次植入后1只眼(7.1%)的偏心大于1.0mm。倾斜超过10度的分别出现在7眼(16.7%)和2眼(14.2%)。两组之间的偏心率大于1.0 mm(卡方= 0.194,P = .834)或倾斜度大于10度(卡方= 0.834,P = .659)在统计学上无显着差异。结论:经巩膜植入后,极少出现临床上显着的IOL倾斜或偏心。在一次和二次植入之间,倾斜或偏心没有差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号