PURPOSE: To report the clinical results of small incision lenticule extraction to correct refractive errors using a femtosecond laser to refine the femtosecond lenticule extraction technique. SETTING: Private laser center, Vadodara, India. DESIGN: Prospective clinical study. METHODS: The VisuMax femtosecond laser system was used to perform small incision lenticule extraction to treat refractive errors. The laser was used to cut a refractive lenticule intrastromally to correct myopia and myopic astigmatism. The lenticule was then extracted from the stroma through a 3.0 to 5.0 mm incision. Outcome measures were corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), and manifest refraction during 6 months of follow-up. Corneal topography and ocular wavefront aberrations were also measured. RESULTS: The study enrolled 51 eyes of 41 patients. The mean spherical equivalent was -4.87 diopters (D) +/- 2.16 (SD) preoperatively and +0.03 +/- 0.30 D 6 months postoperatively. Refractive stability was achieved within 1 month (P<.01). Six months after surgery, 79% of all full-correction cases had a UDVA of 20/25 or better. The 6-month postoperative CDVA was the same as or better than the preoperative CDVA in 95% of eyes. Two eyes lost 1 line of CDVA. CONCLUSION: All-in-one femtosecond refractive correction using a small incision technique was safe, predictable, and effective in treating myopia and myopic astigmatism. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
机译:目的:报告小切口小透镜摘除术的临床结果,以纠正使用飞秒激光的屈光不正,以改善飞秒摘除术的技术。地点:印度瓦多达拉私人激光中心。设计:前瞻性临床研究。方法:使用VisuMax飞秒激光系统执行小切口小透镜摘除术以治疗屈光不正。用激光切割屈光小孔,矫正近视和近视散光。然后通过3.0至5.0mm的切口从基质中提取微孔。结果指标为矫正远视力(CDVA),未矫正远视力(UDVA)以及在随访的6个月内表现出屈光。还测量了角膜地形图和眼波前像差。结果:该研究纳入了41例患者的51只眼。术前平均球当量为-4.87屈光度(D)+/- 2.16(SD),术后6个月为+0.03 +/- 0.30D。 1个月内达到屈光稳定性(P <.01)。手术六个月后,所有完全矫正病例中有79%的UDVA为20/25或更高。在95%的眼睛中,术后6个月的CDVA与术前的CDVA相同或更好。两只眼睛失去了1行CDVA。结论:采用小切口技术进行的飞秒合一屈光矫正治疗近视和近视散光是安全,可预测且有效的。财务披露:没有任何作者对所提及的任何材料或方法有财务或所有权利益。在脚注中可以找到其他披露内容。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号