OBJECTIVE: Baroreflex sensitivity (BRS) is an important prognostic index in cardiovascular diseases, however, its use is complicated by different methods difficult to compare and standardize, often providing conflicting results. We tested whether the simple ratio of RR interval to systolic blood pressure global variabilities (assessed by standard deviations) is a reliable measure of BRS, by measuring the agreement with six established methods. In addition, we tested whether high-pass filtering of data, by removing slow non-baroreflex-mediated fluctuations, could improve the agreement between different BRS methods. METHODS: In 1,409 subjects, we compared 6 established methods (derived by cross-spectral and sequence analysis) and the new method, supine and in response to tilting (1,175 subjects). Data were analyzed after linear detrending, high-pass filtering at 0.025 and 0.05 Hz. RESULTS: Although all seven methods showed a general agreement, the new method consistently showed the lowest distance from the median of the remaining methods (0.04 +/- 0.06 ms/mmHg over 2,584 files, p < 0.05 with respect to the second best method). High-pass filtering improved (p < 0.001) the agreement between methods without reducing the sensitivity to changes induced by tilting. Only the new method could provide estimates in all 2,584 files tested. INTERPRETATION: The new method intercepts the mean information of all other methods better than any other method, hence providing a simple, easy to standardize (no mathematical constraints) and yet robust and reliable BRS estimate. High-pass filtering markedly improves the agreement of all methods, without loss of sensitivity, and could be routinely used in clinical trials, to provide comparable BRS estimates.
机译:目的:压力反射敏感性(BRS)是心血管疾病的重要预后指标,但是,由于难以比较和标准化的各种方法使它的使用变得复杂,常常会产生矛盾的结果。我们通过使用六种既定方法测量一致性,测试了RR间隔与收缩压全局变异性的简单比率(通过标准差评估)是否是BRS的可靠度量。此外,我们测试了通过消除缓慢的非压力反射介导的波动来对数据进行高通滤波是否可以改善不同BRS方法之间的一致性。方法:在1,409名受试者中,我们比较了6种既定方法(通过交叉光谱和序列分析得出)和新方法(仰卧和倾斜)(1,175名受试者)。在0.025和0.05 Hz的线性去趋势,高通滤波之后分析数据。结果:尽管所有七种方法均显示出总体一致,但新方法始终显示出与其余方法的中位数之间的最小距离(在2,584个文件中为0.04 +/- 0.06 ms / mmHg,对于第二好的方法,p <0.05) 。高通滤波改善了方法之间的一致性(p <0.001),而不降低对倾斜引起的变化的敏感性。只有新方法才能提供所有测试的2584个文件中的估计值。解释:新方法比任何其他方法都能更好地拦截所有其他方法的均值信息,因此提供了一种简单,易于标准化(无数学约束)且鲁棒且可靠的BRS估计。高通滤波可以显着改善所有方法的一致性,而不会降低灵敏度,并且可以在临床试验中常规使用,以提供可比的BRS估算值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号