首页> 外文期刊>Sleep >Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep.
【24h】

Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep.

机译:验证了一种新的非侵入性方法来测量血压并评估早产儿睡眠期间的压力反射敏感性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

STUDY OBJECTIVES: Accuracy and precision of a noninvasive device for continuously measuring blood pressure (BP) (Finometer, FMS, The Netherlands) during sleep was assessed in preterm infants. DESIGN: Absolute BP beat-to-beat values, interbeat changes, measurement precision, and baroreflex sensitivity were compared with BP measurements from intraarterial catheters. PARTICIPANTS: Ten preterm infants (gestational age 27-36 weeks; birth weight 964-2620 gm) were studied in the neonatal intensive care unit. MEASUREMENTS AND RESULTS: The 2 modes of BP measurement were compared in 2-minute epochs (n = 10-12/infant). Mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure were analyzed beat to beat, and baroreflex sensitivity was assessed using spontaneous sequence analysis. Mean differences for absolute BP (mm Hg) were as follows: mean arterial pressure, 3 (limits of agreement, -1 to 8); systolic arterial pressure, -4 (-8 to 1); and diastolic arterial pressure, 7 (4 to 10). Mean differences and limits of agreement for interbeat changes were essentially 0 for mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure. Precision (+/- 95% confidence intervals, mm Hg) for the Finometer were mean arterial pressure +/- 7, systolic arterial pressure +/- 8, and diastolic arterial pressure +/- 6. Precision was greater for the arterial catheter (mean arterial pressure +/- 3, systolic arterial pressure +/- 4, and diastolic arterial pressure +/- 4). Baroreflex sensitivity calculated from the Finometer BP was (mean +/- SEM, ms/mm Hg) 1.74 +/- 0.23 and, from the catheter system, BP was 1.56 +/- 0.21 (p value NS). CONCLUSIONS: The Finometer provides accurate measurements of beat-to-beat BP and baroreflex sensitivity. The ability to continuously measure BP and baroreflex sensitivity during sleep in infants may provide vital clues into pathologic conditions associated with impaired autonomic control during sleep.
机译:研究目的:对早产儿睡眠期间连续测量血压(BP)(Finometer,FMS,荷兰)的无创设备的准确性和精确性进行了评估。设计:将绝对的BP搏动值,搏动间的变化,测量精度和压力反射敏感性与动脉导管内的BP测量值进行了比较。参与者:在新生儿重症监护病房中研究了10名早产儿(胎龄27-36周;出生体重964-2620 gm)。测量和结果:在2分钟内比较了两种BP测量模式(n = 10-12 /婴儿)。逐次分析平均动脉压,收缩期动脉压和舒张期动脉压,并使用自发序列分析评估压力反射敏感性。绝对血压的平均差异(毫米汞柱)如下:平均动脉压3(一致极限,-1至8);收缩动脉压-4(-8至1);和舒张期动脉压为7(4至10)。节拍间变化的平均差异和一致性极限对于平均动脉压,收缩期动脉压和舒张期动脉压基本为0。 Finometer的精度(+/- 95%置信区间,mm Hg)为平均动脉压+/- 7,收缩压+/- 8,舒张压+/- 6。平均动脉压+/- 3,收缩压+/- 4和舒张压+/- 4)。根据Finometer BP计算得出的压力反射敏感性为(平均值+/- SEM,ms / mm Hg)1.74 +/- 0.23,根据导管系统,BP为1.56 +/- 0.21(p值NS)。结论:Finometer可精确测量搏动间的血压和压力反射敏感性。连续测量婴儿睡眠期间的BP和压力反射敏感性的能力可能为与睡眠期间自主神经控制受损相关的病理状况提供重要线索。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号