...
首页> 外文期刊>Journal of Cerebral Blood Flow and Metabolism: Official Journal of the International Society of Cerebral Blood Flow and Metabolism >Comparison of cerebral blood flow measurement with [O-15]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review
【24h】

Comparison of cerebral blood flow measurement with [O-15]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review

机译:[O-15]-水正电子发射断层扫描与动脉自旋标记磁共振成像对脑血流测量的比较:系统评价

获取原文
获取原文并翻译 | 示例

摘要

Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [O-15]-water radiotracer. Although [O-15]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [O-15]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.
机译:脑血流的非侵入性成像可提供关键信息,以了解正常的大脑生理以及识别和管理患有神经系统疾病的患者。迄今为止,脑血流测量的参考标准被认为是使用[O-15]-水放射性示踪剂注射的正电子发射断层扫描。尽管[O-15]-水已用于研究正常和病理条件下的脑灌注,但由于需要现场回旋加速器,动脉血采样的侵入性和实验性,它并未在临床中广泛使用。复杂。作为替代方案,动脉自旋标记是一种很有前途的磁共振成像技术,可以在动脉血流入大脑以磁性方式标记脑血流时对其进行磁性标记。随着动脉自旋标记在研究和临床环境中被更广泛地采用,人们努力寻求使该方法标准化并针对基于正电子发射断层扫描的脑血流量测量来验证其脑血流量值。这项工作的目的是批判性地审查同时进行[O-15]-水正电子发射断层扫描和动脉自旋标记以测量脑灌注的研究,目的是更好地了解相对于正电子的动脉自旋标记的准确性和可重复性放射断层扫描参考标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号