首页> 外文期刊>Journal of Biomechanics >Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees
【24h】

Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees

机译:胫骨假体对准变化对被截肢者行走过程中面外承窝反应力矩的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Alignment of lower limb prostheses is important for the gait of amputees. Observed deviations in a particular plane are corrected by altering the prosthetic alignment of the same plane. The assumption is that observed deviations are due to alignment errors within the same plane, but no research has confirmed this assumption. Therefore, the aim of this study was to investigate the out-of-plane effect of systematic alignment changes on socket reaction moments measured by an instrumented prosthesis alignment component in the sagittal and coronal planes in eleven amputees with transtibial prostheses. Each subject walked at self-selected walking speed following randomized controlled angular (±3° and ±6°) and translational (±5. mm and ±10. mm) alignment changes from the nominally aligned condition. The following socket reaction moment parameters were subsequently analyzed: 3 parameters (maximum moment, minimum moment, moment at 45% of stance phase) in the sagittal plane and 2 parameters (moment at 30% and 75% of stance phase) in the coronal plane. A statistical comparison was performed between the nominally aligned and mal-aligned conditions using a repeated measures of ANOVA followed by Scheffe's post-hoc tests. Significant differences were found between the nominally aligned (-0.077±0.078. Nm/kg) and 3° extension (-0.033±0.075. Nm/kg; P=0.0258) and 6° extension (-0.029±0.071. Nm/kg; P=0.0098) conditions in the coronal plane socket reaction moments measured at 30% of stance. Our analysis suggests that the alignment of the transtibial prosthesis should be performed in the sagittal plane first followed by the coronal plane.
机译:下肢假体的对准对于截肢者的步态很重要。通过更改同一平面的假体对齐,可以校正在特定平面中观察到的偏差。该假设是观察到的偏差是由于同一平面内的对准误差引起的,但是尚无研究证实该假设。因此,本研究的目的是研究在经胫骨假体的十一名截肢者中,在矢状和冠状平面中,通过仪器上的假体对准组件测量的系统对准变化对插槽反应力矩的面外影响。每个受试者以自选的行走速度行走,其跟随随机控制的角度(±3°和±6°)和平移(±5。mm和±10。mm)的对齐方式从名义对齐状态发生变化。随后分析了以下承窝反应力矩参数:矢状面中的3个参数(最大矩,最小矩,姿态相的45%处的力矩)和冠状面中的2个参数(矩相的30%和75%处的力矩) 。使用重复测量的方差分析(ANOVA),然后进行Scheffe的事后检验,对名义对齐和不良对齐条件之间进行统计比较。发现名义对准(-0.077±0.078。Nm / kg)和3°延伸(-0.033±0.075。Nm / kg; P = 0.0258)和6°延伸(-0.029±0.071。Nm / kg; P = 0.0098)条件下在冠状平面窝反应力矩为30%的姿势下测得。我们的分析表明,胫骨假体的对齐应首先在矢状面内进行,然后再在冠状面内进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号