...
首页> 外文期刊>The Journal of Bone and Joint Surgery. American Volume >Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age.
【24h】

Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age.

机译:年龄小于50岁的患者使用非骨水泥髋臼组件和骨水泥股骨组件进行全髋关节置换。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: We have been using hybrid total hip arthroplasty (a cementless acetabular component and a cemented stem) in young patients. The purpose of this study was to determine the prevalence of aseptic loosening, polyethylene wear, and osteolysis after the use of this technique. METHODS: We studied a prospective consecutive series of sixty-four primary hybrid total hip replacements in fifty-five patients younger than fifty years old. There were forty-three men and twelve women; the average age at the time of the index operation was 43.4 years. The average duration of follow-up was 9.4 years. We used a cementless acetabular component without screw-holes and a cemented femoral component with a 22-mm head in all hips. Clinical follow-up with use of Harris hip ratings and radiographic follow-up were performed at six weeks; at three, six, and twelve months; and yearly thereafter. The sequential annual linear and volumetric wear rates were measured, and bone-remodeling and osteolysis were assessed. RESULTS: The mean preoperative Harris hip score was 44 points, which increased to 95 points at the time of final follow-up. No hip had aseptic loosening. One hip (2%) was revised because of late infection. The average linear wear (and standard deviation) was 0.96 +/- 0.066 mm, with an average annual rate of 0.096 +/- 0.013 mm. The average volumetric wear was 364.7 +/- 25.2 mm (3), with an average annual rate of 43.4 +/- 3.5 mm (3). Six hips (9%) had an osteolytic lesion of <1 cm in diameter in the calcar femorale (zone 7). CONCLUSIONS: Our results show that a hybrid arthroplasty with a cementless acetabular component and a smooth cemented femoral component (Ra, 0.6 mm) is effective for primary total hip replacement in young patients. Although there was no aseptic loosening and a low prevalence of osteolysis at the latest follow-up evaluation, the high rates of linear and volumetric wear of the polyethylene liner in these young patients remain a concern.
机译:背景:我们一直在年轻患者中使用混合全髋关节置换术(无骨水泥髋臼组件和骨干)。这项研究的目的是确定使用该技术后无菌性松动,聚乙烯磨损和溶骨的发生率。方法:我们对年龄在五十岁以下的五十五名患者进行了前瞻性连续研究,共收集了六十四种主要的混合性全髋关节置换术。一共有四十三男十二女。进行索引操作时的平均年龄为43.4岁。平均随访时间为9.4年。我们使用无螺钉孔的无骨水泥髋臼组件和所有髋部头部均为22mm的骨水泥股骨组件。在6周时进行了Harris髋关节评分和X线片随访的临床随访。在三个,六个和十二个月时;此后每年。测量了连续的年线性和体积磨损率,并评估了骨重塑和骨溶解。结果:术前Harris髋关节平均得分为44分,在最终随访时上升至95分。没有臀部出现无菌性松动。因感染较晚而翻修了一只髋关节(占2%)。平均线性磨损(和标准偏差)为0.96 +/- 0.066毫米,年平均磨损率为0.096 +/- 0.013毫米。平均体积磨损为364.7 +/- 25.2毫米(3),年平均磨损率为43.4 +/- 3.5毫米(3)。股骨总car骨(第7区)中有六个髋部(占9%)的溶骨性病变直径小于1厘米。结论:我们的结果表明,混合髋臼置换术采用非骨水泥髋臼组件和平滑骨水泥股骨组件(Ra,0.6 mm)可以有效地替代年轻患者的全髋关节置换术。尽管在最新的随访评估中没有出现无菌性松动和骨溶解发生率低的趋势,但这些年轻患者中聚乙烯内衬的线性和容积磨损率仍然很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号