We describe a case of symptomatic focal femoral osteolysis around a screw hole distal to the hydroxyapatite-coated portion of a cannulated femoral component in a revision hip replacement. No locking screw had been inserted into this, the most proximal of the three distal holes for locking screws. The presence of polyethylene wear debris in the tissue excised from the lesion suggested that it had passed through the cannulated portion of the stem and out of the proximal unfilled distal locking hole, initiating an osteolytic reaction in an otherwise well-fixed stem. This case highlights an important design characteristic of such cannulated, uncemented femoral components. We recommend that the proximal aperture of these cannulated stems be occluded at implantation.
机译:我们描述了在髋关节翻修术中股骨头假体的羟基磷灰石涂层部分远端的螺丝孔周围出现症状性局灶性股骨骨溶解的情况。没有将锁定螺钉插入其中,这是三个用于锁定螺钉的远端孔中最靠近的孔。从病变处切除的组织中存在聚乙烯磨损碎片,这表明聚乙烯磨损碎片已经穿过茎的插管部分,并从近端未充满的远端锁定孔中流出,从而在原本固定良好的茎中引发了溶骨反应。这种情况突出了这种插管的,非骨水泥化的股骨组件的重要设计特征。我们建议在植入时将这些空心茎的近端孔闭塞。