首页> 外文期刊>The Journal of Bone and Joint Surgery. American Volume >Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems.
【24h】

Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems.

机译:人体膝关节的人体测量:与当前膝关节置换系统的尺寸相关。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: There is a paucity of data concerning the morphological dimensions of the distal part of the femur, the proximal part of the tibia, and the patella. The objective of this study was to analyze the exact anatomic data collected from a large group of patients undergoing total knee arthroplasty and to correlate the measurements to the dimensions of current prosthetic systems. METHODS: Eight different centers collected morphologic data from the distal part of the femur, the proximal part of the tibia, and the patella from 337 knees during total knee arthroplasty. Microcaliper measurements from templates and measuring guides were used to decrease intraobserver variation. The study included 188 women (209 knees) and 107 men (128 knees) who had a mean age of sixty-nine years. A characterization of the aspect ratio (the medial-lateral to anterior-posterior dimensions) was made for the proximal aspect of the tibia and the distal part of the femur. Known dimensions from six prosthetic knee systems were compared with the morphologic data. RESULTS: A wide variation in the aspect ratio for the femoral component was seen among the six different prosthetic systems. For women, there was a significant association between the component size and the amount of medial-lateral overhang, with larger sizes having more overhang (p < 0.0001). Although the femoral aspect ratio for the morphologic data showed higher ratios for smaller knees and proportionally lower ratios for larger knees, the designs showed little change in the aspect ratio. The tibial aspect ratio from the morphologic data showed a higher ratio for smaller knees and a proportionally lower ratio for larger knees. The Duracon component tracked the decline in aspect ratio fairly well, whereas the other brands either did not change with anterior-posterior dimension or actually increased (NexGen). Gender differences in the morphologic data were shown by the variable tibial aspect ratios. A comparison of the bone dimensions from the study data and the dimensions of the implants indicated that the smaller sizes were too small while the larger sizes tended to be too large. The average overall unresected patellar thickness was 23.7 mm. CONCLUSION: The results of this study will allow manufacturers to make more appropriate determinations of the sizes and aspect ratios of components for use in total knee arthroplasty.
机译:背景:关于股骨远端,胫骨近端和the骨的形态学方面的数据很少。这项研究的目的是分析从一大批接受全膝关节置换术的患者中收集的确切解剖数据,并将测量结果与当前假体系统的尺寸相关联。方法:八个膝关节中心在全膝关节置换术中收集了来自337个膝盖的股骨远端,胫骨近端和the骨的形态学数据。使用模板和测量指南中的微量卡尺测量来减少观察者内部差异。该研究纳入了188名女性(209膝)和107名男性(128膝),平均年龄为69岁。对胫骨的近端和股骨的远端进行了长宽比(内侧到外侧到前后尺寸)的表征。将六个膝关节假体的已知尺寸与形态学数据进行比较。结果:在六个不同的修复系统中,股骨组件的长宽比差异很大。对于女性,部件尺寸与内侧-外侧突出量之间存在显着关联,较大尺寸的突出量更大(p <0.0001)。尽管形态数据的股骨长宽比在较小的膝盖上显示较高的比率,在较大的膝盖上按比例显示较低的比率,但设计显示长宽比的变化很小。从形态学数据来看,胫骨纵横比对于较小的膝盖显示较高的比例,而对于较大的膝盖显示比例较低的比例。 Duracon组件很好地跟踪了长宽比的下降,而其他品牌要么没有随前后尺寸变化,要么实际上有所增加(NexGen)。通过可变的胫骨纵横比显示形态学数据中的性别差异。根据研究数据和植入物尺寸对骨骼尺寸的比较表明,较小的尺寸太小,而较大的尺寸往往太大。未切除pa骨的平均总厚度为23.7 mm。结论:这项研究的结果将使制造商能够更适当地确定用于全膝关节置换术的部件的尺寸和纵横比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号