A complete system for real-time PCR detection of Listeria spp. was validated in 5 food matrices and 5 environmental surfaces, namely, hot dogs, roast beef, lox (smoked salmon), pasteurized whole cows' milk, dry infant formula, stainless steel, plastic cutting boards, ceramic tiles, rubber sheets and sealed concrete. The system consists of the MicroSEQReg.Listeria spp. Detection Kit, 2 sample preparation kits (PrepSEQReg. Nucleic Acid Extraction Kit and PrepSEQ Rapid Spin Sample Preparation Kit), the Applied Biosystems 7500 Fast Real-Time PCR instrument, and the RapidFinderTM Express v1.1 Software for data analysis. The test method was compared to the ISO 11290-1 reference method using an unpaired study design. The MicroSEQ Listeria spp. Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all matrixes except hot dogs. For hot dogs, the MicroSEQ method detected more positives than the reference method for the low- and high-level inoculations, with all of the presumptive positives confirmed by the reference method. An independent validation study confirmed these findings on lox and stainless steel surface. The MicroSEQ kit detected all 50 Listeria strains tested and none of the 31 nontarget bacteria strains.
机译:用于李斯特菌属物种实时PCR检测的完整系统。在5种食品基质和5种环境表面上得到验证,即热狗,烤牛肉,熏鲑鱼(熏鲑鱼),巴氏杀菌全脂牛奶,婴儿配方奶粉,不锈钢,塑料砧板,瓷砖,橡胶板和密封混凝土。该系统由MicroSEQ Reg。 Listeria spp组成。检测试剂盒,2个样品制备试剂盒(PrepSEQ Reg。 核酸提取试剂盒和PrepSEQ快速旋转样品制备试剂盒),Applied Biosystems 7500快速实时PCR仪器和RapidFinder TM Express v1.1软件进行数据分析。使用未配对的研究设计,将测试方法与ISO 11290-1参考方法进行了比较。 MicroSEQ李斯特菌属。检测工具包和ISO 11290-1参考方法显示了基于除热狗以外的所有矩阵的卡方分析的等效检测。对于热狗,对于低水平和高水平接种,MicroSEQ方法比参考方法检测到更多阳性,所有推定阳性均通过参考方法确认。一项独立的验证研究证实了在熏氧和不锈钢表面上的这些发现。 MicroSEQ试剂盒检测到所有50个测试的李斯特菌菌株,没有检测到31个非靶细菌菌株。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号