The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for the screening of postmortem blood for amphetamine and methamphetamine and to choose the more appropriate assay for screening. Forty-seven postmortem whole blood specimens were obtained from drug-involved deaths, which had been screened and confirmed positive for methamphetamine and/or amphetamine. Eighty-five negative specimens were obtained from non-amphetamines-involved deaths, 17 of which involved decomposition. Specimens were tested using the Neogen Amphetamine Ultra and Neogen Methamphetamine/MDMA microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays, and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of amphetamines concentrations encountered in medical examiner specimens. True positives, true negatives, false positives, and false negatives were determined relative to gas chromatography-mass spectrometry (GC-MS) and graphed for the ELISA. From these graphs and the receiver operating curves (ROC), the optimal cut-off for the Neogen Methamphetamine/MDMA ELISA was 50 ng/mL methamphetamine equivalents and the optimum cut-off for the Neogen Amphetamine Ultra ELISA was 100 ng/mL amphetamine equivalents. The Neogen Methamphetamine ELISA had a sensitivity of 93.6% +/- 3.5% and a specificity of 77.6% +/- 4.5% versus GC-MS at the cut-off of 50-ng/mL methamphetamine equivalents. The Neogen Amphetamine Ultra ELISA had a sensitivity of 95.7% +/- 3.0% and a specificity of 72.9% +/- 5.2% versus GC-MS at the 100-ng/mL amphetamine equivalents cut-off. The areas under the ROCs were equivalent for the two ELISA assays.
机译:这项研究的目的是评估Neogen公司的微量滴定板酶联免疫测定(ELISA)在筛查死后血液中苯丙胺和甲基苯丙胺的适用性,并选择更合适的测定方法进行筛查。从与毒品有关的死亡中获得了47个死后全血标本,这些死亡已经过筛查并确定为甲基苯丙胺和/或苯丙胺阳性。从与非苯丙胺类药物有关的死亡中获得了85个阴性标本,其中17个涉及分解。使用Neogen Amphetamine Ultra和Neogen Methamphetamine / MDMA微量滴定板ELISA分析法对样品进行测试。在这些测定中未发现全血对基质的影响,因此选择了1:5的稀释度以方便移液并将微量滴定板ELISA测定的IC50置于医学检验员标本中遇到的苯丙胺浓度范围内。相对于气相色谱-质谱(GC-MS)确定真阳性,真阴性,假阳性和假阴性,并绘制出ELISA图。从这些图和接收器工作曲线(ROC),Neogen Methamphetamine / MDMA ELISA的最佳临界值为50 ng / mL甲基苯丙胺,Neogen Amphetamine Ultra ELISA的最佳临界值为100 ng / mL苯丙胺当量。与GC-MS相比,在截止浓度为50 ng / mL的甲基苯丙胺当量时,Neogen Methamphetamine ELISA的灵敏度为93.6%+/- 3.5%,特异性为77.6%+/- 4.5%。与GC-MS相比,Neogen Amphetamine Ultra ELISA在100 ng / mL苯丙胺当量截止值时的灵敏度为95.7%+/- 3.0%,特异性为72.9%+/- 5.2%。 ROC下的面积对于两种ELISA分析而言是等效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号