The BD ProbeTec CT Q~x Amplified DNA Assay and the BD ProbeTec GC Q~x Amplified DNA Assay (both BD Diagnostics, Sparks, MD) represent two new assays developed for use with the BD Viper System with XTR Technology (BD Diagnostics). These assays were built on the foundation of the former BD ProbeTec ET assays (BD Diagnostics) and its accompanying instrumentation. The study described below compared the new assay format, Extracted Mode, to the former assay format, Nonextracted Mode, with the primary objective of examining and measuring overall time expenditures and efficiency of operation. An 80 - 142-min reduction in "hands-on" total processing time was observed for the Extracted Mode whether testing urines or swabs. The second objective was to assess the accuracy of performance at low simulated analytical loads for the pathogens Chlamydia trachomatis and Neisseria gonorrhoeae. Performance accuracies for simulated positive and negative urine or swab specimens were calculated to be 99.97% for Extracted Mode and 99.76% for Nonextracted Mode.
机译:BD ProbeTec CT Q-x扩增DNA检测和BD ProbeTec GC Q-x扩增DNA检测(BD Diagnostics,Sparks,MD)代表了两个新的检测方法,可用于具有XTR技术的BD Viper系统(BD Diagnostics)。这些测定是在以前的BD ProbeTec ET测定(BD Diagnostics)及其随附仪器的基础上构建的。下文描述的研究将新的测定形式“提取模式”与以前的测定形式“非提取模式”进行了比较,其主要目的是检查和测量总体时间花费和操作效率。无论是测试尿液还是拭子,对于提取模式,观察到的“动手”总处理时间减少了80-142分钟。第二个目标是评估在低模拟分析负荷下沙眼衣原体和淋病奈瑟菌的性能。计算得出的模拟正,负尿液或拭子样本的性能准确度分别为:提取模式为99.97%,非提取模式为99.76%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号