Investigation of RFID tag readability for pharmaceutical products at item level.

机译:在物品级别研究药品的RFID标签可读性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: The applications of radio frequency identification (RFID) technology carry a tremendous potential for pharmaceutical industry. There is a pressing need to analyze the performance of RFID tags attached to various pharmaceutical dosage forms. METHOD: The readability of RFID-tagged pharmaceutical products is, for the first time, systematically investigated by experiments. Factors considered include dosage forms, ion concentration in solution, angle of rotation, and distance between the RFID tag and the interrogator. RESULTS: Compared with empty container, the filling of any representative dosage forms causes deteriorated readability for the tag attached to container. Analysis of variance reveals that the effects of dosage forms, angle of rotation, and their interaction are statistically significant. In addition, an increase in distance (equivalent to higher RF attenuation level) and higher ion concentration in solution beyond a certain level have detrimental effect on tag readability. CONCLUSION: The analysis shows that the RFID tag readability is strongly dependent on the factors that are experimented with. The level of the factors for optimum RFID system performance should be adjusted based on the particular application.
机译:背景:射频识别(RFID)技术的应用为制药业带来了巨大的潜力。迫切需要分析附着在各种药物剂型上的RFID标签的性能。方法:首次通过实验系统地研究了带有RFID标签的药品的可读性。考虑的因素包括剂型,溶液中的离子浓度,旋转角度以及RFID标签与询问器之间的距离。结果:与空容器相比,任何代表性剂型的填充都会导致附着在容器上的标签的可读性下降。方差分析表明,剂型,旋转角度及其相互作用的影响具有统计学意义。另外,距离的增加(相当于更高的RF衰减水平)和溶液中的离子浓度超过一定水平会对标签的可读性产生不利影响。结论:分析表明,RFID标签的可读性在很大程度上取决于所试验的因素。应根据特定应用调整最佳RFID系统性能的因素水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号