摘要

Purpose: To study the reliability of a Non-Instrumented Walk Test in individuals with Parkinson's disease (PD). Method: Thirty individuals (21 Males) with PD were studied. Their mean age was 68.90±9.28 years. The average time since diagnosis was 8.75±5.68 years. The reliability of the manual Non-Instrumented Walk Test was studied while "OFF" and "ON" dopaminergic medication. Subjects walked at their self-selected, usual speed during a Non-Instrumented Walk Test and while walking on a computerized instrumented walkway. Intraclass correlation coefficients (ICCs) were calculated and means were compared for three gait parameters as measured by the two methods. Results: During "OFF" medication testing, ICCs between the Non-Instrumented Walk Test and the instrumented measures for gait speed, cadence and stride length were 0.96 (p < 0.0005), 0.72 (p = 0.001) and 0.97 (p < 0.0005), respectively. During "ON" medication testing, the ICCs were 0.96 (p < 0.0005), 0.86 (p < 0.0005) and 0.96 (p < 0.0005), respectively. The means of the non-instrumented measures tended to be lower than those obtained on the instrumented walkway. Conclusions: The Non-Instrumented Walk Test is a quick, simple and inexpensive gait evaluation for individuals with PD. The method is sufficiently reliable to be used clinically in this population during different medication cycles. Implications for Rehabilitation The Non-Instrumented Walk Test in individuals with PD is reliable. Results supported the use of the measure. This simple walk test is quick and easy to administer in both clinical and community settings.
机译:目的:研究帕金森氏病(PD)患者非器械行走测试的可靠性。方法:研究了30例PD患者(21例男性)。他们的平均年龄为68.90±9.28岁。自诊断以来的平均时间为8.75±5.68年。在“ OFF”和“ ON”的多巴胺能药物治疗期间,研究了手动非器械行走测试的可靠性。在非仪器步行测试期间以及在计算机化的人行道上行走时,受试者以自己选择的通常速度行走。计算类内相关系数(ICC),并比较两种方法测得的三个步态参数的平均值。结果:在“关闭”药物测试过程中,非器械行走测试与步态速度,节奏和步幅长度的仪器测量值之间的ICC分别为0.96(p <0.0005),0.72(p = 0.001)和0.97(p <0.0005) , 分别。在“开”式药物测试期间,ICC分别为0.96(p <0.0005),0.86(p <0.0005)和0.96(p <0.0005)。非仪表措施的手段往往要比在仪器人行道上获得的手段要低。结论:非器械行走测试是针对PD患者的快速,简单且廉价的步态评估。该方法具有足够的可靠性,可以在不同的用药周期内在该人群中临床使用。康复的意义PD患者的非器械行走测试是可靠的。结果支持该度量的使用。这种简单的步行测试可在临床和社区环境中快速简便地进行管理。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号