Objective: In 1981 McKinlay described "Seven Stages in the Career of a Medical Innovation". We wished to examine whether the model fits a modern device life cycle, and to comment on device manufacturers' influence on the life cycle. We chose to study the complete life cycle of TVT Secur, a mesh kit for surgical treatment of stress urinary incontinence in women, from its marketing in 2006 to device discontinuation for commercial reasons in March 2013. Methods: A PubMed review was undertaken to identify all published literature related to TVT Secur from 2006 to November 2014. Each publication was classified according to McKinlay's seven stages. Results: Eighty-three relevant publications from 22 countries were identified: 4 promising reports, 1 professional adoption, 0 third-party endorsement, 34 standard procedure, 19 randomised controlled trials (RCTs) from 2010 and mainly describing comparisons with other TVT family members), 0 professional denunciation of RCT findings, and 4 erosion and discreditation. Conclusions: McKinlay's seven stages model was useful to describe TVT Secur's truncated life cycle. TVT Secur, fully approved and licensed according to all jurisdictional requirements, generated many descriptive cohort studies but more rigorous RCT evidence appeared only half way through its life cycle. Device discontinuation meant that the stage of erosion and discreditation described by McKinlay occurred after TVT Secur was no longer available. We suggest that careful premarket evaluation of safety and effectiveness might decrease the need for commercial discontinuation of devices, and that post-marketing evaluation is a crucial mechanism to protect patients from harm.
机译:目标:1981年,麦金莱(McKinlay)描述了“医疗创新事业的七个阶段”。我们希望检查该模型是否适合现代设备的生命周期,并评论设备制造商对生命周期的影响。我们选择研究TVT Secur(用于治疗女性压力性尿失禁的手术工具的网状套件)的完整生命周期,从2006年投放市场到出于商业原因于2013年3月停止使用设备。方法:进行了PubMed审查,以确定所有在2006年至2014年11月期间发表了与TVT Secur有关的文献。每个出版物均根据麦金莱(McKinlay)的七个阶段进行分类。结果:确定了22个国家/地区的83种相关出版物:2010年以来的4份有希望的报告,1份专业采用,0份第三方认可,34份标准程序,19项随机对照试验(RCT),主要描述了与其他TVT家族成员的比较) ,0项专业谴责RCT的发现,以及4项侵蚀和歧视。结论:麦金莱的七个阶段模型对于描述TVT Secur的截短生命周期很有用。 TVT Secur根据所有司法管辖区的要求得到完全批准和许可,产生了许多描述性队列研究,但更严格的RCT证据仅在其生命周期的一半出现。设备中断意味着McKinlay所述的腐蚀和分散阶段发生在TVT Secur不再可用之后。我们建议认真进行安全性和有效性的上市前评估可能会减少对器械商业停产的需求,而上市后评估是保护患者免受伤害的重要机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号